Back Button HT7022A Datasheet HTML 3Page - Holtek Semiconductor Inc HT7022A Datasheet HTML 4Page - Holtek Semiconductor Inc HT7022A Datasheet HTML 5Page - Holtek Semiconductor Inc HT7022A Datasheet HTML 6Page - Holtek Semiconductor Inc HT7022A Datasheet HTML 7Page - Holtek Semiconductor Inc HT7022A Datasheet HTML 8Page - Holtek Semiconductor Inc HT7022A Datasheet HTML 9Page - Holtek Semiconductor Inc HT7022A Datasheet HTML 10Page - Holtek Semiconductor Inc HT7022A Datasheet HTML 11Page - Holtek Semiconductor Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 16 page
background image
HT70XX
Rev. 1.60
7
January 14, 2003
The hysteresis width is:
VHYS =VDET (+)
- VDET (-)
The figure demonstrates the NMOS output type with
positive output polarity (VOUT is normally open, active
low). The HT70XX series also supplies options for other
output types with active high outputs. Application cir-
cuits shown are examples of positive output polarity
(normally open, active low) unless otherwise specified.
V S S
V D D
R A
R B
R C
M 1
M N
C o m p a r a t o r
V O U T
R L
V R E .
V B
V C
NMOS output voltage detector (HT70XXA)
Application Circuits
Microcomputer reset circuit
Normally a reset circuit is required to protect the micro-
computer system from malfunctions due to power line
interruptions. The following examples show how differ-
ent output configurations perform a reset function in var-
ious systems.
· NMOS open drain output application for separate
power supply
· NMOS open drain output application with R-C delay
Power-on reset circuit
With several external components, the NMOS open
drain type of the HT70XX series can be used to perform
a power-on reset function as shown:
H T 7 0 X X A
V D D
V S S
V O U T
M i c r o -
c o m p u t e r
C
R
V D D 2
V D D 1
R E S E T
H T 7 0 X X A
V S S
V O U T
M i c r o -
c o m p u t e r
H T 7 0 4 4 A
V O U T
V S S
R
D
V I N
V D D
C
t
V D D
t
V O U T
V O U T
V S S



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com