| Electronic Components Datasheet Search |
|
UM0432 Datasheet(PDF) 39 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
UM0432 Datasheet(HTML) 39 Page - STMicroelectronics |
|
39 / 53 page ![]() UM0432 Motor control operations 39/53 During any state: idle, start, run or brake, a blinking red LED together with the brake of the motor indicates a fault condition. A fault condition is due to one of the following: ● hardware overcurrent: current flowing inside the motor reaches a value greater than the maximum allowed current of 7.65 A – see Section 7.4.16. ● Over-voltage: the bus voltage reaches a value greater than 29 Vac. ● Over-temperature: the on-board temperature sensor measures a temperature greater than 110° C. ● Start-up failed: the start-up phase ends without getting a sufficient number of valid zero crossing events. ● Motor stalled: during the running of the motor no zero crossing events have been observed. Note: Blinking of the red LED during the running of the motor indicates that a software current limitation is in action. 7.5.6 Changing the real-time parameters The real-time parameters can be changed using the potentiometers of the control board. Table 15 explains the potentiometer functionality based on the driving strategy. If during the GUI configuration phase the "from RV1" control was unchecked, the value of the duty cycle (or the value of the current reference) is not set by P1 but has a fixed value. If during the GUI configuration phase the "from RV2 - RV3" control was unchecked, the value of the rising delay coefficient and the value of the falling delay coefficient are not set by P2 and P3 but have fixed values. The maximum duty cycle allowed in voltage mode depends on the value of the PWM frequency and the value of the PWM minimum off time set by the GUI. Table 15. Potentiometer functionality based on open/closed loop driving strategy Voltage mode Open loop Closed loop P1 Sets the duty cycle percentage from 0% to the maximum duty cycle allowed. Sets the target rotor frequency value from the minimum value to the maximum value configured (see Section 7.4.4) P2 Sets the value of the rising delay coefficient from 0 to 255 P3 Sets the value of the falling delay coefficient from 0 to 255 P4 Not used Current mode Open loop Closed loop P1 Sets the current reference value from 0 A to the maximum current allowed. Sets the target rotor frequency value from the minimum value to the maximum value configured (see Section 7.4.4) P2 Sets the value of the rising delay coefficient from 0 to 255 P3 Sets the value of the falling delay coefficient from 0 to 255 P4 Not used |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |