10 / 20 page ![]() Reset control AN2339 10/20 4 Reset control There are two types of internal hardware reset, defined as System Reset and Global Reset. The STR91x device also provides a Reset output signal. 4.1 Reset input 4.1.1 System Reset A system reset resets all registers except the Clock Control Register, PLL Configuration Register, System Status Register, Flash Configuration register, Protection register and the FMI Bank address and Bank size Registers. A system reset is generated when one of the following events occurs: ● A low level on the RESET_INn pin (External Reset): – This input signal is active low. It has no internal pull-up to VDDQ. A valid active-low input signal of tRINMIN = 100ns. ● JTAG Reset Command (JTAG reset): The JTAG interface has two reset signals connected to the debug target hardware: – nTRST drives the JTAG nTRST signal on the ARM processor core. It is an open collector output that is activated whenever the In-Circuit Emulators (ICE) software has to re-initialize the debug interface in the target system. – nSRST is a bidirectional signal that both drives and senses the system reset signal on the target. The open collector output is driven LOW by the debugger to re-initialize the target system. ● Watchdog reset – In Watchdog mode, a reset is generated when the counter reaches the end of count. For more details, refer to Section 5.1: JTAG interface on page 12 Note: If the nRESET and nTRST signals are linked together, resetting the system also resets the TAP controller. 4.1.2 Global Reset A global reset sets all the registers to their reset values, it is generated when one of the following events occurs: LVD circuitry LVD circuitry will always cause a global reset if the CPU VDD source drops below it’s fixed threshold of 1.4V. However, the LVD trigger threshold to cause a global reset for the I/O ring’s VDDQ source is set to one of two different levels, depending on the VDDQ operating range. If VDDQ operation is at 2.7V to 3.3V, the LVD dropout trigger threshold is 2.4V. If VDDQ operation is 3.0V and 3.6V, the LVD threshold is 2.7V. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |