| Electronic Components Datasheet Search |
|
MAX1854 Datasheet(PDF) 3 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1854 Datasheet(HTML) 3 Page - Maxim Integrated Products |
|
3 / 33 page ![]() High-Speed, Adjustable, Synchronous Step-Down Controllers with Integrated Voltage Positioning _______________________________________________________________________________________ 3 ELECTRICAL CHARACTERISTICS (continued) (Circuit of Figure 1, V+ = +15V, VCC = VDD = 5V, SKIP = VCC, VPS = PGND, TA = 0°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS BIAS AND REFERENCE Quiescent Supply Current (VCC)ICC Measured at VCC, FB forced above the regulation point 700 950 µA Quiescent Supply Current (VDD)IDD Measured at VDD, FB forced above the regulation point <1 5 µA Quiescent Supply Current (V+) I+ 25 40 µA Shutdown Supply Current (VCC) SHDN = GND <1 5 µA Shutdown Supply Current (VDD) SHDN = GND <1 5 µA Shutdown Supply Current (V+) SHDN = GND, VCC = VDD = 0 or 5V <1 5 µA Reference Voltage VREF VCC = 4.5V to 5.5V, no external REF load 1.98 2 2.02 V Reference Load Regulation IREF = 0 to 50 µA 0.01 V REF Sink Current IREF REF in regulation 10 µA REF Fault Lockout Voltage Falling edge 1.6 V FAULT PROTECTION MAX1716 1.8 1.9 2.0 Output Overvoltage Fault Threshold (Note 5) Measured at FB MAX1855 1.97 2.0 2.03 V Output Overvoltage Fault Propagation Delay (Note 5) FB forced to 2% above trip threshold (MAX1716/MAX1855 only) 1.5 µs Output Undervoltage Fault Threshold (Foldback) 35 40 45 % Output Undervoltage Fault Propagation Delay FB forced to 2% below trip threshold 10 µs Output Undervoltage Fault Blanking Time (Foldback) From SHDN signal going high 10 30 ms Current-Limit Threshold (Positive, Default) VITH VPGND - VCS, ILIM = VCC 110 120 130 mV VILIM = 0.5V 40 50 60 Current-Limit Threshold (Positive, Adjustable) VITH VPGND - VCS VILIM = 2V (REF) 170 200 230 mV Negative Current-Limit Threshold VPGND - VCS -1.2 × VITH mV Zero-Crossing Current-Limit Threshold VPGND - VCS 3mV Thermal Shutdown Threshold Hysteresis = 10°C 150 °C VCC Undervoltage Lockout Threshold Rising edge, hysteresis = 20mV, switching disabled below this level 4.0 4.45 V |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |