Electronic Components Datasheet Search
  English  ▼

X  

M78A Datasheet(PDF) 2 Page - Minmax Technology Co., Ltd.

Part # M78A
Description  Low Ripple and Noise
PDF  3 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MINMAX [Minmax Technology Co., Ltd.]
Direct Link  http://www.minmax.com.tw
Logo MINMAX - Minmax Technology Co., Ltd.

M78A Datasheet(HTML) 2 Page - Minmax Technology Co., Ltd.

  M78A Datasheet HTML 1Page - Minmax Technology Co., Ltd. M78A Datasheet HTML 2Page - Minmax Technology Co., Ltd. M78A Datasheet HTML 3Page - Minmax Technology Co., Ltd.  
Zoom Inzoom in Zoom Outzoom out
 2 / 3 page
background image
M78A
Switching Regulator 0.5A, SIP Package
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2014/04/15 REV:6
Page 2 of 3
®
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
I/O Isolation Voltage
None
Switching Frequency
280
330
380
KHz
MTBF(calculated)
MIL-HDBK-217F@25
℃, Ground Benign
2,000,000
---
---
Hours
Environmental Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
Operating Ambient Temperature Range (See Power Derating Curve)
Natural Convection
-40
---
+90
℃
Case Temperature
---
---
+100
℃
Storage Temperature
-55
---
+125
℃
Thermal Shutdown
Internal IC junction
---
160
---
℃
Humidity (non condensing)
---
---
95
% rel. H
Lead-free reflow solder process(1.5mm from case for 10Sec.)
---
---
260
℃
EMC Specifications
Parameter
Standards & Level
Performance
Conducted EMI
Compliance to EN55022 and FCC part 15
Class B (See Page 3)
Radiated Emissions
EN55022
Class B
ESD
EN61000-4-2 air±8KV
Class A
Radiated immunity
EN61000-4-3 3V/m
Class A
Fast transient (4)
EN61000-4-4 ±0.5KV
Class A
Conducted immunity
EN61000-4-6 3Vrms
Class A
Magnetic Field Immunity
EN61000-4-8 3A/m
Class A
Power Derating Curve
Notes
1
Specifications typical at Ta=+25
℃, resistive load, nominal input voltage, rated output current unless otherwise noted.
2
Other input and output voltage may be available, please contact factory.
3
We recommend to protect the converter by a slow blow fuse in the input supply line.
4
The M78A series can meet EN61000-4-4 by adding a capacitor across the input pins. Suggested capacitor CHEMI-CON KY 330µF/100V.
5
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
6
With a input capacitor 22µF/50V for input voltage >28VDC, the input voltage allows 32VDC, max.
7
Specifications are subject to change without notice.



Html Pages

1 2 3


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com