| Electronic Components Datasheet Search |
|
MAX4172ESA Datasheet(PDF) 7 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX4172ESA Datasheet(HTML) 7 Page - Maxim Integrated Products |
|
7 / 8 page ![]() • Accuracy: A high RSENSE value allows lower cur- rents to be measured more accurately. This is because offsets become less significant when the sense voltage is larger. For best performance, select RSENSE to provide approximately 100mV of sense voltage for the full-scale current in each application. • Efficiency and Power Dissipation: At high current levels, the I2R losses in RSENSE can be significant. Take this into consideration when choosing the resistor value and its power dissipation (wattage) rating. Also, the sense resistor’s value might drift if it is allowed to heat up excessively. • Inductance: Keep inductance low if ISENSE has a large high-frequency component. Wire-wound resis- tors have the highest inductance, while metal film is somewhat better. Low-inductance metal-film resis- tors are also available. Instead of being spiral wrapped around a core, as in metal-film or wire- wound resistors, they are a straight band of metal and are available in values under 1 Ω. • Cost: If the cost of RSENSE is an issue, you might want to use an alternative solution, as shown in Figure 2. This solution uses the PC board traces to create a sense resistor. Because of the inaccura- cies of the copper resistor, the full-scale current value must be adjusted with a potentiometer. Also, copper’s resistance temperature coefficient is fairly high (approximately 0.4%/°C). In Figure 2, assume that the load current to be mea- sured is 10A, and that you have determined a 0.3-inch- wide, 2-ounce copper to be appropriate. The resistivity of 0.1-inch-wide, 2-ounce (70µm thickness) copper is 30m Ω/ft. For 10A, you might want RSENSE = 5mΩ for a 50mV drop at full scale. This resistor requires about 2 inches of 0.1-inch-wide copper trace. Current-Sense Adjustment (Resistor Range, Output Adjust) Choose ROUT after selecting RSENSE. Choose ROUT to obtain the full-scale voltage you require, given the full- scale IOUT determined by RSENSE. OUT’s high imped- ance permits using ROUT values up to 200k Ω with minimal error. OUT’s load impedance (e.g., the input of an op amp or ADC) must be much greater than ROUT (e.g., 100 x ROUT) to avoid degrading measurement accuracy. High-Current Measurement The MAX4172 can achieve high-current measurements by using low-value sense resistors, which can be paral- leled to further increase the current-sense limit. As an alternative, PC board traces can be adjusted over a wide range. Low-Cost, Precision, High-Side Current-Sense Amplifier _______________________________________________________________________________________ 7 3.48 3.48 3.48 100 1 3.48 3.48 OUTPUT RESISTOR, ROUT (k Ω) 3.48 0.348 10 10 3.48 3.48 3.48 FULL-SCALE OUTPUT VOLTAGE, VOUT (V) 0.696 20 5 34.8 FULL-SCALE LOAD CURRENT (A) SCALE FACTOR, VOUT/ISENSE (V/A) 1000 0.1 CURRENT-SENSE RESISTOR, RSENSE (mΩ) Table 1. Suggested Component Values OUT GND 1 O.1 in. COPPER VSENSE RSENSE INPUT LOAD/BATTERY VSUPPLY ROUT O.3 in. COPPER O.3 in. COPPER 2 8 RS+ RS- V+ 3V TO 32V MAX4172 6 5 Figure 2. MAX4172 Connections Showing Use of PC Board |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |