10 / 18 page ![]() -48V Hot-Swap Controllers with External RSENSE and High Gate Pulldown Current 10 ______________________________________________________________________________________ If the voltage between VEE and SENSE reaches the cur- rent-limit trip voltage (VCL), the MAX5921/MAX5939 pull down the GATE and regulate the current through the external MOSFET such that VSENSE - VEE < VCL. If the current drawn by the load drops below VCL / RSENSE limit, the GATE voltage rises again. However, if the load current is at the regulation limit of VCL / RSENSE for a peri- od of tPHLCL, the electronic circuit breaker trips, causing the MAX5921/MAX5939 to turn off the external MOSFET. After an overcurrent fault condition, the MAX5921 auto- matically restarts after tOFF has elapsed. The MAX5939 circuit breaker is reset by toggling UV or by cycling power. Unless power is cycled to the MAX5939, the device waits until tOFF has elapsed before turning on the gate of the external FET. Load-Current Regulation The MAX5921/MAX5939 accomplish load-current regu- lation by pulling current from GATE whenever VSENSE - VEE > VCL. This decreases the gate-to-source voltage of the external MOSFET, thereby reducing the load current. When VSENSE - VEE < VCL, the MAX5921/MAX5939 pulls GATE high by a 45µA (IPU) current. Exponential Current Regulation The MAX5921/MAX5939 provide an exponential pull- down current to turn off the external FET in response to overcurrent conditions. The GATE pulldown current increases (see Typical Operating Characteristics) in response to VSENSE - VEE potentials greater than 50mV (VCL). Load Current Regulation (Short-Circuit Condition) The MAX5921/MAX5939 devices also include a very fast high-current pulldown source connected to GATE (see Typical Operating Characteristics). The high-cur- rent pulldown activates if VSENSE exceeds VEE by 650mV (typ) during a catastrophic overcurrent or short- circuit fault condition. The high-current pulldown circuit sinks as much as 450mA from GATE to turn off the external MOSFET. Immunity to Input Voltage Steps The MAX5921/MAX5939 guard against input voltage steps on the input supply. A rapid increase in the input supply voltage (VDD - VEE increasing) causes a current step equal to I = CL x ∆VIN / ∆t, proportional to the input voltage slew rate ( ∆VIN / ∆t). If the load current exceeds VCL / RSENSE during an input voltage step, the MAX5921/ MAX5939 current limit activates, pulling down the gate voltage and limiting the load current to VCL / RSENSE. The DRAIN voltage (VDRAIN) then slews at a slower rate than the input voltage. As the drain voltage starts to slew down, the drain-to-gate feedback capacitor C2 pushes back on the gate, reducing the gate-to-source voltage (VGS) and the current through the external MOSFET. Once the input supply reaches its final value, the DRAIN slew rate (and therefore the inrush current) is limited by the capacitor C2 just as it is limited in the startup condi- tion (see the Power-Supply Ramping section). To ensure correct operation, RSENSE must be chosen to provide a current limit larger than the sum of the load current and the dynamic current into the load capacitance in the slewing mode. If the load current plus the capacitive charging current is below the current limit, the circuit breaker does not trip. Undervoltage and Overvoltage Protection Use UV and OV to detect undervoltage and overvoltage conditions. UV and OV internally connect to analog com- parators with 130mV (UV) and 50mV (OV) of hysteresis. When the UV voltage falls below its threshold or the OV voltage rises above its threshold, GATE pulls low. GATE is held low until UV goes high and OV is low, indicating that the input supply voltage is within specification. The MAX5921/MAX5939 includes an internal lockout (UVLO) that keeps the external MOSFET off until the input supply voltage exceeds 15.4V, regardless of the UV input. UV is also used to reset the circuit breaker after a fault condition has occurred. Pull UV below VUVL to reset the circuit breaker. GATE - VEE 10V/div VEE 50V/div DRAIN 50V/div INRUSH CURRENT 1A/div 4ms/div Figure 6b. Inrush Control Waveforms |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |