| Electronic Components Datasheet Search |
|
MAX7480ESA Datasheet(PDF) 7 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX7480ESA Datasheet(HTML) 7 Page - Maxim Integrated Products |
|
7 / 8 page ![]() 8th-Order, Lowpass, Butterworth, Switched-Capacitor Filter _______________________________________________________________________________________ 7 Clock Signal External Clock The MAX7480 SCF is designed for use with external clocks that have a 40% to 60% duty cycle. When using an external clock with these devices, drive CLK with a CMOS gate powered from 0 to VDD. Varying the rate of the external clock adjusts the corner frequency of the filter as follows: fC = fCLK / 100 Internal Clock When using the internal oscillator, connect a capacitor (COSC) between CLK and ground. The value of the capacitor determines the oscillator frequency as follows: Minimize the stray capacitance at CLK so that it does not affect the internal oscillator frequency. Vary the rate of the internal oscillator to adjust the filter’s corner fre- quency by a 100:1 clock to corner-frequency ratio. For example, an internal oscillator frequency of 100kHz produces a nominal corner frequency of 1kHz. Input Impedance vs. Clock Frequencies The MAX7480’s input impedance is effectively that of a switched-capacitor resistor, and is inversely proportion- al to frequency. The input impedance values deter- mined below represent the average input impedance, since the input current is not continuous. As a rule, use a driver with an output impedance less than 10% of the filter’s input impedance. Estimate the input impedance of the filter using the following formula: where fCLK = clock frequency and CIN = 2.31pF. Low-Power Shutdown Mode This device features a shutdown mode that is activated by driving SHDN low. In shutdown mode, the filter’s sup- ply current reduces to 0.2µA (typ) and its output becomes high impedance. For normal operation, drive SHDN high or connect to VDD. ___________Applications Information Offset and Common-Mode Input Adjustment The voltage at COM sets the common-mode input volt- age and is biased at mid-supply with an internal resis- tor-divider. Bypass COM with a 0.1µF capacitor and connect OS to COM. For applications requiring offset adjustment or DC level shifting, apply an external bias voltage through a resistor-divider network to OS, as shown in Figure 3. (Note: Do not leave OS unconnect- ed.) The output voltage is represented by this equation: VOUT = (VIN - VCOM) + VOS with VCOM = VDD / 2 (typical), where (VIN - VCOM) is lowpass-filtered by the SCF and VOS is added at the output stage. See the Electrical Characteristics for the voltage range of COM and OS. Changing the voltage on COM or OS significantly from mid-supply reduces the filter’s dynamic range. Power Supplies The MAX7480 operates from a single +5V supply. Bypass VDD to GND with a 0.1µF capacitor. If dual supplies (±2.5V) are required, connect COM to system ground and connect GND to the negative supply. Figure 4 shows an example of dual-supply operation. Single- and dual-supply performances are equivalent. For either single- or dual-supply operation, drive CLK and SHDN from GND (V- in dual-supply operation) to VDD. For ±5V dual-supply applications, use the MAX291–MAX297. Input Signal Amplitude Range The optimal input signal range is determined by observ- ing the voltage level at which the total harmonic distor- tion plus noise (THD+N) is minimized for a given corner frequency. The Typical Operating Characteristics shows a graph of the device’s THD+N response as the input signal’s peak-to-peak amplitude is varied. This measurement is made with OS and COM biased at mid- supply. Z 1 f C IN CLK IN = () ⋅ f (kHz) C ; C in pF OSC 3 OSC OSC = ⋅ 53 10 VDD VSUPPLY IN CLK GND INPUT OUTPUT 50k 50k 50k OUT 0.1 µF 0.1 µF 0.1 µF CLOCK SHDN COM OS MAX7480 Figure 3. Offset Adjustment Circuit |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |