13 / 27 page ![]() BL6528 Single-phase Multifunction Metering IC 13 / 27 V1.0 Frequency output The BL6528 provides two energy-to-frequency conversion for calibration purpose. After initial calibration at manufacturing, the manufacturer or end customer is often required to verify the meter accuracy. One convenient way to do this is to provide an output frequency that is proportional to the reactive power. This output frequency provides a simple single-wire interface that can be optically isolated to interface to external calibration equipment. BL6528 includes two programmable calibration frequency output PINs (CF_WATT, CF_VAR). The digital-to-frequency converters are used to generate the pulse output. The pulse output stays high for 90ms if the pulse period is longer than 180ms. If the pulse period is shorter than 180ms, the duty cycle of de pulse output is 50%. The maximum output frequency with ac inputs at full scale and with CFDIV=010H is approximately 0.5 kHz. The BL6528 can set the CF frequency through the CF_DIV register. The default value of the CFDIV register is 001H (HEX). When set CFDIV[x]=1, the CF frequency is 2 (x-4)*CF CFDIV=010H. Reactive Power Signal Process LPF2 LPF2 Hilbert 1 Hilbert 2 × LPF1 × 2Ah VARGN + 0Ch VA ʃ 11h VARHR ANTI-CREEP VAR 30h VAR_CREEP 2Eh VAR_LOS 29h VAROS ʃ T 14h LINE_VARHR D to F CF_VAR 33h CFDIV 35h LINECYC IA_WAVE IB_WAVE V_WAVE Reactive power offset calibration BL6528 contains the reactive power offset calibration (VAROS). This register is in 12-bit sign magnitude format, the default value is 000H. The offset can exist in the power calculations due to crosstalk between channels on the PCB and in the BL6528. The reactive power offset calibration allows these offsets to be removed to increase the accuracy of the measurement at low input power levels. VAROS Re Re 0 r activePowe r activePowe Reactive power gain adjustment The gain register (VARGN) is used to adjust the active power measurement range. This register is in 12-bit sign magnitude format, the default value is 000H. The following formula shows how to adjust the output reactive power: |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |