| Electronic Components Datasheet Search |
|
HP203B Datasheet(PDF) 13 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
HP203B Datasheet(HTML) 13 Page - List of Unclassifed Manufacturers |
|
13 / 18 page ![]() DataSheet HP203B number and its unit is in 0.02 mbar. When setting the pressure thresholds, the user must divide the actual thresholds by 0.02, and then convert the result to a 2’s complement number. When the PA_MODE bit is set to 1, the contents stored in these registers are the altitude thresholds. Its value should be a 16-bit 2’s complement number and its unit is in meter. For Example: PA_MODE = 0 (pressure, unit in 0.02 mbar) Threshold Hex Value PA_H_TH_MSB PA_H_TH_LSB 800.06 mbar 0x9C43 0x9C 0x43 900 mbar 0xAFC8 0xAF 0xC8 PA_MODE = 1 (altitude, unit in meter) Threshold Hex Value PA_H_TH_MSB PA_H_TH_LSB 5000 m 0x1388 0x13 0x88 These examples are also applied to setting the pressure (or altitude) middle and lower bound threshold registers as introduced below. 6.2.2 PA_M_TH_LSB, PA_M_TH_MSB - (RW) The two registers form the 16-bit value of PA_M_TH which saves the pressure (or altitude) middle threshold for event detection. Similar to the PA_H_TH, the meaning of their values and the data formats are selected by the PA_MODE bit. 6.2.3 PA_L_TH_LSB, PA_L_TH_MSB - (RW) The two registers form the 16-bit value of PA_L_TH which saves the pressure (or altitude) lower bound threshold for event detection. Similar to the PA_H_TH, the meaning of their values and the data formats are selected by the PA_MODE bit. 6.2.4 T_H_TH - (RW) This register stores the 8-bit temperature threshold for event detection. The data is in 2’s complement format and the unit is in ℃. Threshold Hex Value T_H_TH 45 ℃ 0x2D 0x2D -20 ℃ 0xEC 0xEC For Example: These examples are also applied for setting the temperature middle and lower bound threshold registers as introduced below. 6.2.5 T_M_TH - (RW) This register stores the 8-bit temperature middle threshold for event detection. The data is in 2’s complement format and the unit is in ℃. 6.2.6 T_L_TH - (RW) This register stores the 8-bit temperature lower bound threshold for event detection. The data is in 2’s complement format and the unit is in ℃. 6.2.7 Improper Setting of Thresholds Improperly setting the thresholds, such as setting the lower bound threshold to be larger than the upper bound threshold, will lead to unexpected behavior of the device. It is recommended for the user to check the status of the TH_ERR bit in the INT_SRC register after setting the thresholds into the device. Logic 1 of this bit indicates that improper setting of the thresholds occurs. HP203B_DataSheet_EN_V2.0 www.hoperf.com 13 / 18 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |