Back Button TPS65262 Datasheet HTML 17Page - Texas Instruments TPS65262 Datasheet HTML 18Page - Texas Instruments TPS65262 Datasheet HTML 19Page - Texas Instruments TPS65262 Datasheet HTML 20Page - Texas Instruments TPS65262 Datasheet HTML 21Page - Texas Instruments TPS65262 Datasheet HTML 22Page - Texas Instruments TPS65262 Datasheet HTML 23Page - Texas Instruments TPS65262 Datasheet HTML 24Page - Texas Instruments TPS65262 Datasheet HTML 25Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 75 page
background image
TPS65400-Q1
www.ti.com
SLVSCQ2 – JULY 2015
8.3.7 Fault Handling
OVP, OCP, and undervoltage protection (UVP) are handled for each switcher independently. OVP or OCP faults
that occur on one switcher do not affect the other outputs. There are two exceptions:
•
If current-sharing mode (ISHARE) is detected for a switcher that faults, both switchers in parallel have the
same response to OVP or OCP.
•
When using internal sequencing, in the case of faults occurring during the initial power-up sequence, all
switchers are disabled for 500 ms, after which, the startup sequence is restarted.
During the soft-start time for a switcher, all fault signals (OVP, OCP, and UVP) are disabled and reset to the
unfaulted condition. The first moment when faults can be triggered is after the end of the soft-start sequence.
OVP thresholds are set as a percentage of VREF. A deglitching time of 50
μs is used for the overvoltage. When
an overvoltage occurs at the OVP upper threshold limit, the high-side FET and the low-side FET are disabled for
that switcher until the OVP falling threshold is reached. When the OVP falling threshold is reached, the low-side
FET turns on for 200 ns to ensure that the bootstrap capacitor is recharged before resuming normal operation of
the converter.
Output voltage falling below the UVP thresholds causes the corresponding PGOOD output to fall, but the
switcher continues to operate as it tries to increase the output voltage. However, if the PGOOD terminal is tied to
the enable ENSWx signal of another switcher on the PCB (for external sequencing), the output for that ENSWx-
PGOOD-tied switcher is disabled until output voltage is nominal and PGOOD is good.
OTP shuts down all switchers. When the temperature drops below the hysteresis level, a soft reset is triggered
and the chip restarts from the startup sequence.
Fault Monitoring describes fault reporting and clearing of fault status registers.
The OVP and UVP sensing is deglitched to prevent unwanted tripping. The faults need to be sustained for more
than 55
μs typically (60 μs max) to be registered and trigger protection circuits and PGOOD output to fall. Fault
detection is disabled on a given switcher when its VREF is being ramped (as result of an I2C command to
change VREF). An additional 100-
μs fault blanking time results after VREF has been adjusted to its target level.
8.3.8 OCP for SW1 to SW4
The OCP is I2C-programmable and set by the IOUT_MAX command. By default, the peak current IOUT_MAX for
SW1 and SW2 is 6 A, and for SW3 and SW4 it is 3 A. When the current reaches this threshold, the unit
immediately turns off the high-side FET and keeps the low-side FET off for the remainder of the switching cycle.
The following cycle are skipped (high-side FET off, low-side FET off) regardless of the inductor current. If the
current in the inductor is still higher than the IOUT_MAX after the skipped cycle, the following cycles are also
skipped until the current reach below the IOUT_MAX.
If the IOUT_MAX is reached more than 256 active cycles continuously, the switcher shut downs for 20 ms and
restarts. If the switcher is running in interleaved operation, both the switcher that tripped the IOUT_MAX
threshold and its interleaved counterpart shut down for 20 ms. After that period of time, the unit restarts and goes
through soft-start operation. For very-low duty cycle operation and faulty operation with very-fast current increase
during the high-side FET on-time (due to inductor saturation and so forth), OCP is also enforced on the low side
to ensure no runaway condition exists.
Table 2. Current Limit
Options
SWITCHER
IOUT_MAX
2 A
3 A
SW1, SW2
4 A
5 A
6 A (default)
0.5 A
1 A
SW3, SW4
2 A
3 A (default)
Copyright © 2015, Texas Instruments Incorporated
Submit Documentation Feedback
21
Product Folder Links: TPS65400-Q1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com