ADP3209D Datasheet(PDF) 21 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADP3209D Datasheet(HTML) 21 Page - ON Semiconductor |
|
21 / 27 page ![]() ADP3209D http://onsemi.com 21 provides an approximate value for the switching loss per main MOSFET: PS(MF) + 2 fSW VDC IO nMF RG nMF CISS (eq. 22) where: nMF is the total number of main MOSFETs. RG is the total gate resistance. CISS is the input capacitance of the main MOSFET. The most effective way to reduce switching loss is to use lower gate capacitance devices. The conduction loss of the main MOSFET is given by the following equation: PC(MF) + D IO nMF 2 ) 1 12 IR nMF 2 RDS(MF) (eq. 23) where RDS(MF) is the on resistance of the MOSFET. Typically, a user wants the highest speed (low CISS) device for a main MOSFET, but such a device usually has higher on resistance. Therefore, the user must select a device that meets the total power dissipation (about 0.8 W to 1.0 W for an 8−lead SOIC) when combining the switching and conduction losses. For example, an IRF7821 device can be selected as the main MOSFET (one in total; that is, nMF = 1), with approximately CISS = 1010 pF (maximum) and RDS(MF) = 18 m W (maximum at TJ = 120°C), and an IR7832 device can be selected as the synchronous MOSFET (two in total; that is, nSF = 2), with RDS(SF) = 6.7 mW (maximum at TJ = 120 °C). Solving for the power dissipation per MOSFET at IO = 15 A and IR = 5.0 A yields 178 mW for each synchronous MOSFET and 446 mW for each main MOSFET. A third synchronous MOSFET is an option to further increase the conversion efficiency and reduce thermal stress. Finally, consider the power dissipation in the driver. This is best described in terms of the QG for the MOSFETs and is given by the following equation: PDRV + (eq. 24) fSW 2 n nMF QGMF ) nSF QGSF ) ICC VCC where QGMF is the total gate charge for each main MOSFET, and QGSF is the total gate charge for each synchronous MOSFET. The previous equation also shows the standby dissipation (ICC times the VCC) of the driver. Ramp Resistor Selection The ramp resistor (RR) is used to set the size of the internal PWM ramp. The value of this resistor is chosen to provide the best combination of stability and transient response. Use the following expression to determine a starting value: RR + AR L 3 AD RDS CR RR + 0.2 560 nH 3 5 3.4 mW 5pF + 439 kW (eq. 25) where: AR is the internal ramp amplifier gain. AD is the current balancing amplifier gain. RDS is the total low−side MOSFET on resistance. CR is the internal ramp capacitor value. Another consideration in the selection of RR is the size of the internal ramp voltage (see Equation 26). For stability and noise immunity, keep the ramp size larger than 0.5 V. Taking this into consideration, the value of RR in this example is selected as 340 k W. The internal ramp voltage magnitude can be calculated as follows: VR + AR (1 * D) VVID RR CR fSW VR + 0.2 (1 * 0.062) 1.174 V 340 kW 5pF 390 kHz + 0.33 V (eq. 26) The size of the internal ramp can be increased or decreased. If it is increased, stability and transient response improves but thermal balance degrades. Conversely, if the ramp size is decreased, thermal balance improves but stability and transient response degrade. In the denominator of Equation 25, the factor of 3 sets the minimum ramp size that produces an optimal balance of good stability and transient response. COMP Pin Ramp In addition to the internal ramp, there is a ramp signal on the COMP pin due to the droop voltage and output voltage ramps. This ramp amplitude adds to the internal ramp to produce the following overall ramp signal at the PWM input: VRT + VR 1 * 2 (1*D) fSW CX RO (eq. 27) where CX is the total bulk capacitance, and RO is the droop resistance of the regulator. For this example, the overall ramp signal is 0.23 V. Current Limit Setpoint To select the current limit setpoint, we need to find the resistor value for RLIM. The current limit threshold for the ADP3209D is set when the current in RLIM is equal to the internal reference current of 20 mA. The current in RLIM is equal to the inductor current times RO. RLIM can be found using the following equation: RLIM + ILIM RO 20 mA (eq. 28) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |