| Electronic Components Datasheet Search |
|
GA512R6KV Datasheet(PDF) 2 Page - Wall Industries,Inc. |
|
|
|||||||||||||||||||||||||||||
GA512R6KV Datasheet(HTML) 2 Page - Wall Industries,Inc. |
|
2 / 7 page ![]() Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 GA6KV Series With 6KVDC Isolation Single and Dual Output 2 Watt DC/DC Converter SPECIFICATION TEST CONDITIONS Min Nom Max Unit ENVIRONMENTAL Operating Temperature (Ambient) -25 +60 °C Operating Temperature (Case) -25 +90 °C Storage Temperature -40 +125 °C Humidity 95 % Lead Temperature 1.5mm from case for 10 seconds 260 °C Cooling Free air convection MTBF MIL-HDBK-217F @ 25°C, Ground Benign 600,000 hours PHYSICAL Weight 12.4 grams Dimensions 31.8(L) x 20.3(W) x 10.2(H) mm Case Material Non-conductive black plastic SAFETY Conducted EMI EN55022 Class A OUTPUT VOLTAGE / CURRENT RATING CHART Output Current Input Current Model Number Input Voltage Output Voltage Min Max No Load Max Load Reflected Ripple Current Efficiency (Typ) Max Capacitive Load GA505R6KV 5 VDC 400mA 645mA 62% 680µF GA512R6KV 12 VDC 165mA 629mA 63% 680µF GA515R6KV 15 VDC 133mA 623mA 64% 680µF GA505RD6KV ±5 VDC ±100mA 476mA 42% 270µF GA512RD6KV ±12 VDC ±83mA 699mA 57% 270µF GA515RD6KV 5 VDC (4.5 ~ 5.5 VDC) ±15 VDC 0mA ±66mA 100mA 695mA 15mA (Typ.) 57% 270µF GA1205R6KV 5 VDC 400mA 269mA 62% 680µF GA1212R6KV 12 VDC 165mA 262mA 63% 680µF GA1215R6KV 15 VDC 133mA 260mA 64% 680µF GA1205RD6KV ±5 VDC ±100mA 185mA 45% 270µF GA1212RD6KV ±12 VDC ±83mA 281mA 59% 270µF GA1215RD6KV 12 VDC (10.8 ~ 13.2 VDC) ±15 VDC 0mA ±66mA 50mA 280mA 8mA (Typ.) 59% 270µF GA2405R6KV 5 VDC 400mA 134mA 62% 680µF GA2412R6KV 12 VDC 165mA 131mA 63% 680µF GA2415R6KV 15 VDC 133mA 130mA 64% 680µF GA2405RD6KV ±5 VDC ±100mA 93mA 45% 270µF GA2412RD6KV ±12 VDC ±83mA 143mA 58% 270µF GA2415RD6KV 24 VDC (21.6 ~ 26.4 VDC) ±15 VDC 0mA ±66mA 30mA 142mA 3mA (Typ.) 58% 270µF NOTES 1. Specifications typical at +25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Ripple and noise measured at 20MHz bandwidth. 3. Transient Recovery Time is measured to within 1% error band for a step change in output load of 50% to 100%. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltages may be available, please contact factory. 6. Specifications subject to change without notice. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |