4 / 15 page ![]() NJ88C50 4 The main N divider is programmable so that it can determine how many cycles of each division ratio the external prescaler will perform. The total division ratio of the output from the system VCO to the synthesiser's phase detector may be expressed as NTOT and R1, R2, R3 and R4 are the available prescaler ratios and N1, N2, N3 and N4 are the corresponding number of cycles for each ratio selected, within one complete division cycle. The divider is programmed via the serial data bus and the values needed to be programmed for each of the possible prescaler ratios are as follows:- In 2 modulus mode (division ratios R1, R2) NTOT = N1.R1 + N2.R2 Programmed values needed: N1 - a 12 bit value giving the number of times R1 is to be used N2 - a 8 bit value giving the number of times R2 is to be used In 3 modulus mode (division ratios R1, R2, R3) NTOT = N1.R1 + N2.R2 + N3.R3 Programmed values needed: N1 - a 12 bit value giving the number of times R1 is to be used N2 - a 4 bit value giving the number of times R2 is to be used N2+N3 - a 4 bit value where N3 is the number of times R3 is to be used and (N2+N3) is modulo-16 addition In 4 modulus mode (division ratios R1, R2, R3, R4) NTOT = N1.R1 + N2.R2 + N3.R3 + N4.R4 Programmed values needed: N1 - a 12 bit value giving the number of times R1 is to be used N2 - a 4 bit value giving the number of times R2 is to be used N2+N3 - a 4 bit value where N3 is the number of times R3 is to be used. N2+N3+N4 - a 4 bit value where N4 is the number of times R4 is to be used. (N2+N3) and (N2+N3+N4) are modulo-16 addition. To facilitate the use of multimodulus prescalers the N divider is based upon a twelve bit up/down counter which functions as follows The first value, N1, is loaded into the counter which then counts down from N1 to zero. During this time, the modulus ratio R1 is selected. When the counter reaches zero modulus R2 is selected and the counter then counts up to the N2 value. If 2 modulus operation is chosen, the counter is then reloaded with N1 and the count is repeated. For operation with 3 or 4 modulus devices, the counter continues to count up once it has reached the N2 value. The count continues to the N2+N3 value and during this time the R3 ratio is selected. In the 3 modulus case, when the N2+N3 value is reached the counter is then reloaded with the N1 value and the modulus ratio R1 is selected. For 4 modulus operation the counter will continue its count up to the N2+N3+N4 value before reloading the N1 value. During this time the R4 modulus is selected. If N2, N3, or N4 are set to zero this will give a full count of 16 for the corresponding modulus. The N divider block also has a special control line from the Fractional-N logic. When required this control will cause the total division ratio to be increased from N to N+1. This is achieved by forcing a cycle which would have normally used a prescaler ratio R1 to use ratio R2 instead. R1 and R2 are chosen so that R2 equals R1+1. Further explanation of the operation of the synthesiser when using 2, 3 or 4 modulus prescaler is given in the section on multimodulus division (page 8). The phase detector used on the main synthesiser is similar to the type used on the auxiliary synthesiser (Figure.3). In this case, however, the detector will drive two pairs of complimentary charge pumps, one of which is intended to drive the loop integrator capacitor to provide integral control, whilst the other provides proportional control for the VCO. This system is shown in Fig 5, and has applications where fast locking of the loop is required. MODES OF OPERATION Normal Mode The synthesiser will operate in normal mode while the strobe line of the serial data bus is low. In this mode the following current levels are produced. The charge pump providing the proportional feedback term will have a normal current level designated by Iprop(0), that is set by an external bias resistor, RSM. Iprop(0) will vary when different N-divider ratios are programmed, so that it is proportional to the total division ratio. To avoid the necessity of computing the total division ratio on chip, an eight bit number representing the most significant bits of Ntot will be loaded via the serial data bus. Iprop(0) is therefore given by Iprop(0) = CN.Ibo where CN is the loaded eight bit number and the value Ibo is scaled from the external current setting resistor RSM where Ibo = Irsm/32. Typically Ibo = 1µA ,and therefore Iprop(0) will have a maximum value equal to 255µA. Fig.5 Loop filter using both charge pumps |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |