| Electronic Components Datasheet Search |
|
PCA9564 Datasheet(PDF) 11 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCA9564 Datasheet(HTML) 11 Page - NXP Semiconductors |
|
11 / 31 page ![]() Philips Semiconductors Product data PCA9564 Parallel bus to I2C-bus controller 2003 Apr 02 11 Table 2. Master Transmitter Mode APPLICATION SOFTWARE RESPONSE STATUS CODE STATUS OF THE I2C BUS AND TO I2CCON NEXT ACTION TAKEN BY SIO HARDWARE (I2CSTA) SIO HARDWARE TO/FROM I2CDAT STA STO SI AA 08H A START condition has been transmitted Load SLA+W X X 0 X SLA+W will be transmitted; ACK bit will be received 10H A repeated START Load SLA+W or X X 0 X As above condition has been transmitted Load SLA+R X X 0 X SLA+R will be transmitted; SIO will be switched to MST/REC mode 18H SLA+W has been transmitted; ACK has Load data byte or 0 0 0 X Data byte will be transmitted; ACK bit will be received been received no I2CDAT action or 1 0 0 X Repeated START will be transmitted; no I2CDAT action or 0 1 0 X STOP condition will be transmitted; STO flag will be reset no I2CDAT action 1 1 0 X STOP condition followed by a START condition will be transmitted; STO flag will be reset 20H SLA+W has been transmitted; NOT ACK Load data byte or 0 0 0 X Data byte will be transmitted; ACK bit will be received has been received no I2CDAT action or 1 0 0 X Repeated START will be transmitted; no I2CDAT action or 0 1 0 X STOP condition will be transmitted; STO flag will be reset no I2CDAT action 1 1 0 X STOP condition followed by a START condition will be transmitted; STO flag will be reset 28H Data byte in I2CDAT has been transmitted; Load data byte or 0 0 0 X Data byte will be transmitted; ACK bit will be received ACK has been received no I2CDAT action or 1 0 0 X Repeated START will be transmitted; no I2CDAT action or 0 1 0 X STOP condition will be transmitted; STO flag will be reset no I2CDAT action 1 1 0 X STOP condition followed by a START condition will be transmitted; STO flag will be reset 30H Data byte in I2CDAT has been transmitted; Load data byte or 0 0 0 X Data byte will be transmitted; ACK bit will be received NOT ACK has been no I2CDAT action or 1 0 0 X Repeated START will be transmitted; received no I2CDAT action or 0 1 0 X STOP condition will be transmitted; STO flag will be reset no I2CDAT action 1 1 0 X STOP condition followed by a START condition will be transmitted; STO flag will be reset 38H Arbitration lost in SLA+W or No I2CDAT action or 0 0 0 X I2C-bus will be released; not addressed slave will be entered Data bytes No I2CDAT action 1 0 0 X A START condition will be transmitted when the bus becomes free (STOP or SCL and SDA high) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |