| Electronic Components Datasheet Search |
|
ISO7641FCDWR Datasheet(PDF) 21 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
ISO7641FCDWR Datasheet(HTML) 21 Page - Texas Instruments |
|
21 / 35 page ![]() ISO7631FM, ISO7631FC, ISO7641FC www.ti.com SLLSEC3E – SEPTEMBER 2012 – REVISED AUGUST 2015 Table 1. DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Insulation Characteristics(1) PARAMETER TEST CONDITIONS SPECIFICATION UNIT VIORM Maximum working insulation voltage 1414 VPEAK After Input/Output safety test subgroup 2/3, VPR = VIORM x 1.2, t = 10 s, 1697 Partial discharge < 5 pC Method a, After environmental tests subgroup 1, VPR Input-to-output test voltage VPR = VIORM x 1.6, t = 10 s, 2262 VPEAK Partial Discharge < 5 pC Method b1, 100% Production test VPR = VIORM x 1.875, t = 1 s 2652 Partial discharge < 5 pC VTEST = VIOTM VIOTM Maximum transient overvoltage t = 60 sec (Qualification) 4242 VPEAK t = 1 sec (100% Production) VIO = 500 V, TA = 25°C >1012 RIO (2) Isolation resistance, Input to Output VIO = 500 V, 100°C ≤ TA ≤ 125°C >1011 Ω VIO = 500 V at TS = 150°C >109 CIO (2) Barrier capacitance, Input to Output VI = 0.4 sin (2πft), f = 1MHz 2 pF Pollution degree 2 (1) Climatic Classification 40/125/21 (2) All pins on each side of the barrier tied together creating a two-terminal device. Table 2. IEC 60664-1 Ratings Table PARAMETER TEST CONDITIONS SPECIFICATION Material Group II Rated mains voltage ≤ 300 VRMS I–IV Installation classification / Overvoltage Rated mains voltage ≤ 600 VRMS I–III category for basic insulation Rated mains voltage ≤ 1000 VRMS I–II 9.3.1.1 Regulatory Information VDE TUV CSA UL CQC Certified according Certified according to Approved under CSA Recognized under 1577 Certified according to to DIN V VDE V EN/UL/CSA 60950-1 and Component Acceptance Component Recognition GB4943.1-2011 0884-10 (VDE V 61010-1 Notice 5A, IEC 60950-1 Program 0884-10):2006-12 and IEC 61010-1 and DIN EN 61010- 1 (VDE 0411- 1):2011-07 Basic Insulation 3000 VRMS Reinforced Maximum Transient Insulation, 400 VRMS Reinforced Insulation, Overvoltage, 4242 maximum working voltage Single Protection, 2500 Altitude ≤ 5000 m, Tropical 3000 VRMS Isolation Rating VPK 3000 VRMS Basic Insulation, VRMS (1) Climate, 250 VRMS Maximum Working 600 VRMS maximum working Maximum Working Voltage Voltage, 1414 VPK voltage Certificate number: Certificate number: Master contract number: File number: E181974 Certificate number: 40016131 U8V 13 09 77311 010 220991 CQC14001109542 (1) Production tested ≥ 3000 VRMS for 1 second in accordance with UL 1577. Copyright © 2012–2015, Texas Instruments Incorporated Submit Documentation Feedback 21 Product Folder Links: ISO7631FM ISO7631FC ISO7641FC |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |