  UPD7720AC Datasheet HTML 1Page - NEC UPD7720AC Datasheet HTML 2Page - NEC UPD7720AC Datasheet HTML 3Page - NEC UPD7720AC Datasheet HTML 4Page - NEC UPD7720AC Datasheet HTML 5Page - NEC UPD7720AC Datasheet HTML 6Page - NEC UPD7720AC Datasheet HTML 7Page - NEC UPD7720AC Datasheet HTML 8Page - NEC UPD7720AC Datasheet HTML 9Page - NEC Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 12 page
background image
NEC Electronics Inc.
Roseville Manufacturing
4
Table 1. Reliability Tests
The major reliability tests performed by NEC consist of high-temperature bias (HTB), 85°C/85% relative humidity (T/H),
high-temperature storage life (HTSL), and high-humidity storage life (HHSL) tests. Additionally, various environmental
and mechanical tests are performed. This table shows the conditions of the various life tests, environmental tests, and
mechanical tests.
Test Item
Symbol
MIL-STD 883C Method
Condition
Remarks
High-temperature bias
life
HTB
1005
TA = 125°C,
VCC = 5.5 V.
Note 1
High-temperature storage
life
HTSL
1008
TA = 150°C.
Note 1
Temperature and
humidity life
T/H
TA = 85°C,
RH = 85%.
VDD = 5.5 V, alternate
pin bias.
Notes 1, 2
High-humidity storage
life
HHSL
TA = 85°C,
RH = 85%.
Notes 1, 2
Pressure cooker
PCT
TA = 125°C,
RH = 100%
P = 2.3 atm.
Notes 1, 2
Temperature cycle
T/C
1010
−65° to 150°C, 1 hour/
cycle.
Note 1
Lead fatigue
LI
2004
125g (DIP) 250g (QFP),
three bends, 90
°, without
breaking.
Note 4
Solderability
SD
2003
TA = 230°C, 5 sec, rosin-
based flux.
Note 5
Soldering heat
TS
Note 3
260
°C, 10 sec, rosin
based flux.
215
°C VPS
235
°C, IR reflow
DIP
PLCC
QFP
Temperature cycle
1010
10 cycles,
−65° to 150°C.
Thermal shock
1011
15 cycles, 0
° to 100°C.
Note 1
Notes:
1. Electrical test per data sheet is performed. Devices that exceed the data sheet limits are considered rejects.
2. Pretreatment as specified.
3. MIL-STD 750A, method 2031.
4. Broken lead is considered a reject.
5. Less than 95% coverage is considered a reject.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com