| Electronic Components Datasheet Search |
|
APS75-30 Datasheet(PDF) 2 Page - DENSEI-LAMBDA |
|
|
|||||||||||||||||||||||||||||
APS75-30 Datasheet(HTML) 2 Page - DENSEI-LAMBDA |
|
2 / 2 page ![]() These operating instructions do not purport to cover all details or variation in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the Purchaser ユs purposes, the matter should be referred to the local Sales Office. The contents of these operating instructions shall not become part or modify any prior or existing agreement, commitment or relationship. The Sales Contract contains the entire obligations. The warranty contained in the contract between the parties is the sole warranty. Any statements contained herein do not create new warranties or modify the existing warranty. For the purpose of this operating instructions and product labels,“Danger “ indicates death, severe personal injury or substantial property damage will result if proper precautions are not taken. For the purpose of this operating instructions and product labels,“Warning” indicates death, severe personal injury or substantial property damage can result it proper precautions are not taken. For the purpose of this operating instructions and product labels, “Caution” indicates minor personal injury or property damage can result if proper precautions are not taken. 114.1 104 (2) 12 16.75 19.4 8.6 ±1.5 DIN EN50022 35X7.5 Input Terminal Input Terminal LED =NOTES= *1 At 100/200VAC,Ta = 25 ℃ and maximum output power. *2 For cases where conformance to various safety specs (UL,CSA,EN) are required, input voltage range will be 100~230VAC(50/60Hz). *3 Not applicable for the in-rush current to Noise Filter less than 0.2ms. *4 Measure with JEITA RC-9131 probe, Bandwise of scope : 100MHz, and Please refer to Fig. A for measurement of ripple voltage. *5 85~264VAC,constant load at Line Regulation. No load-full load at Load Regulation. *6 Constant current limit with automatic recovery. Avoid to operate over load or dead short for 30seconds. *7 OVP circuit will shutdown output, manual reset. *8 Measure by the each measuring method of UL,CSA,EN (at 60Hz). *9 At 100VAC maximum output current. *10 Refer to OUTPUT DERATING CURVE (BB018-01-03_) APS75-30 Specification ■APS75-30 Specifications (Please refer to Instruction manual before use) ■ Basic Connection MODEL ITEM APS75-30 30VDC 0A 2.4A 72W 80% 85 ∼ 264VAC 50Hz /60Hz (47Hz∼63Hz) 1.9A /1.2A (1.6A at 115VAC) 18A at 100VAC, 40A at 230VAC, Ta=25 ℃, Cold Start Fixed 150m Vpp ±1% ±2% 2.8A ∼4.8A 115% ∼ 0.2mA(Typ) at 100VAC /0.45mA(Typ) at 230VAC 20ms at 100VAC -10 ℃∼+50℃: 100%, +55℃: 70% 30% ∼90%RH(No dewdrop) -30 ℃∼+85℃ 10% ∼95%RH(No dewdrop) Convection Cooling Input - FG: 2kVAC (20mA), Input - Output: 3kVAC(20mA) , Output - FG: 500VDC(100mA)for 1 min More than 100M Ω at 25℃ and 70%RH, Output - FG...500VDC Mounting DIN rail : 10Hz ∼55Hz, Half-wave Amplitude 0.5mm (1 hour), Mounting screw: 10Hz∼55Hz, Half-wave Amplitude 1mm (1 hour) Mounting DIN rail : 150m/s2 (11ms), Mounting screw: 300m/s2 (18ms) Apploved by UL1950, CSA950(C-UL), EN60950(TU . . V), Built to meet EN50295(AS-i) Built to meet EN55011-B, EN55022-B, FCC-ClassB, VCCI-B Built to meet EN55011-B, EN55022-B, FCC-ClassB, VCCI-B Built to meet EN50082-2, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6 Noise Voltage : 2kV (Nomal, Common), pulse Width : 1us (Pulse Rise 1ns) IP20 620g 45 × 135 × 105 mm (Refer to Outline Drawing) 【APS75-30】 APS75-30 Derating Curve Unit :mm Measurement point for ripple Voltage Fig. A AS-i - LineGND AS-I+ A 0.1uF ■ Output Derating Curve OUTPUT DERATING CURVE 0 20 40 60 80 100 -10 0 10 20 30 40 50 60 Ta (℃) MOUNTING : STANDARD MOUNTING ONLY Outline drawing APS75-30 Instruction Manual BEFORE USING THIS PRODUCT 1. Terminal Explanation DANGER WARNING CAUTION 1 L1 : Input terminal Live line 2 N : Input terminal Neutral line 3 FG : Frame Ground 4 POWER INDICATOR LED (Lights green during power output) 5 AS-i + : AS-i Output terminal 6 AS-i + : AS-i Output terminal 7 Live GND : Live ground (Isolated from input FG) 8 AS-i ー:AS-i Output terminal 9 AS-i ー:AS-i Output terminal ■Outline APS75-30 was developed to meet AS-Interface (Actuator Sensor Interface) requirement. AS-Interface is a kind of international open network for FA application as the actuator-sensor level of the architecture. AS-Interface applies one cable only that supplies the signal and electric power stably together, so that will make cost saving and cable reduction possible. ■Feature ●AS-Interface Power Supply ●Global scale wide input range: AC85-264V ●Output: 30V 2.4A max. ●DIN rail mountable type ■Safety standard ■AS-i ■EMC ●Immunity : Comform to EN50082-2 EN61000-4-2 (Electrostatics discharge) EN61000-4-3 (Radiated electromagnetic field) EN61000-4-4 (Electrical fast transient) EN61000-4-5 (Surge) EN61000-4-6 (Induced electromagnetic field) CONFORM EN55011-B, EN55022-B CONFORM VCCI-B CONFORM FCC-B APPROVE EN50295(AS-i) APPROVE AS-International Association(No.37901) MEET Low Voltage Directive APPROVE UL1950,CSA950 (C-UL) APPROVE EN60950 (TUV) . . EMI Radiated Emisson Noise 1. Nominal Output Voltage 2. Minimum Output Current 3. Maximum Output Current 4. Maximum Output Power 5. Efficiency (Typ) (*1) 6. Input Voltage Range (*2) 7. Input Frequency 8. Input Current(100/200VAC)(Typ) 9. Inrush Current(Typ) (*3) 10. Output Voltage Range 11. Maximum Ripple & Noise (*4) 12. Initial Setting Voltage (*1) 13. Maximum Line & Load (*5) & temperature Regulation 14. Over Current Protection (*6) 15. Over Voltage Protection(Typ) (*7) 16. Leakage Current (*8) 17. Hold-up Time (Typ) (*9) 18. Operating Temperature (*10) 19. Operating Humidity 20. Storage Temperature 21. Storage Humidity 22. Cooling 23. Withstand Voltage 24. Isolation Resistance 25. Vibration (IEC68-2-6) 26. Shock (IEC68-2-27) 27. Safety 28. Conducted Emission 29. Radiated Emission 30. Immunity 31. Impulse Noise Simulation 32. Degree of Protection (IEC529) 33. Weight(Typ.) 34. Size (W ×H×D) ASi-En-中身(刷り色P655CVC) 02.2.14 4:13pm ページ1 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |