10 / 28 page ![]() 10 ICS1702 Charging System Test The system test mode is intended for use in applications where the charging system functionality needs to be tested. The system test sequence consists of a one second activation of the CMN, MMN and PFN indicator pins as well as the CHG and DCHG lines. The OTN indicator is not activated. The system test mode is entered by placing both the AUX0 and AUX1 pins low (L). The ICS1702 shuts down after the test sequence is finished and a master reset must be performed to reactivate the device. Cold Battery Charging Cold battery charging is activated if a voltage at the THERM pin is in the cold battery voltage range, as shown in Figure 9. The ICS1702 checks for a cold battery before initiating fast charge. If a cold battery is present before fast charge begins, the ICS1702 begins a two-hour C/10 topping charge (the pulsed duty cycle is based on the selected charge rate). If the battery is still cold after the two hour topping charge is complete, the ICS1702 begins a C/40 maintenance charge. The maintenance charge will continue for as long as the battery remains cold Unless the ten hour time mode is selected. The thermistor voltage at the THERM pin is checked every second to see if the battery has warmed up. If so, the ICS1702 stops the topping or maintenance charge and begins a fast charge at a rate selected by the SEL0 and SEL1 inputs. A cold battery does not interfere with the condition mode, direct maintenance mode, the discharge portion of the discharge-to- charge mode, or the discharge-only mode as programmed by the AUX0 and AUX1 pins. See the section on Temperature Sensing, for more information. The MMN and OTN indicators will be active, indicating that a low current charge is being applied to a battery that is outside the specified temperature range for fast charging. If the CMN and OTN indicators are active see the Application Information section. Direct Maintenance Mode The ICS1702 can enter directly into the C/40 maintenance mode for cells that require a maintenance charge only. The direct maintenance mode is activated by setting the AUX0 pin low (L) and the AUX1 pin high (H), and resetting the device. The SEL0 and SEL1 pins must be set based on the charging current and the battery capacity. The formula Charging Current (Amps) Battery Capacity (Amp • hr) gives the charge rate. Use Table 4 to find the correct SEL0 and SEL1 settings. The maintenance charge is applied until the battery is removed, upon which the ICS1702 will enter the polling detect mode. The ICS1702 will enter the direct maintenance mode upon initial power-up or after a master reset. The MMN indicator will be active during this mode. Conditioning Mode The ICS1702 can enter a conditioning mode which applies a C/10 charge for a timed 10 hour period, followed by an indefinite C/40 maintenance charge until the batteries are removed. The conditioning mode can be entered by setting the AUX0 pin high (H) and the AUX1 pin open (Z). The SEL0 and SEL1 pins must be set based on the charging current and the battery capacity. The formula Charging Current (Amps) Battery Capacity (Amp • hr) gives the charge rate. Use Table 4 to find the correct SEL0 and SEL1 settings. The MMN indicator will be active during the 10 hour conditioning charge and the maintenance charge that follows. The ICS1702 enters the polling detect mode if the battery is removed. Ten Hour Timer Mode Placing the AUX0 and AUX1 pins both high (H) enables a ten hour timer. This timer limits the total charge, including the maintenance charge, to approximately ten hours for a battery that is completely discharged before fast charge is initiated. The ten hour limit is based on the assumption that the charge terminates due to the fast charge timer as shown in Table 2 Table 2: Ten Hour Timer Information Charge Rate Fast Charge Timer Cutoff Maintenance Timer Cutoff (after fast charge termination) Charge Time Limit (from reset) 4 C 0.3 hrs 9.7 hrs 10 hrs 2 C 0.6 hrs 9.4 hrs 10 hrs 1.3 C 0.9 hrs 9.1 hrs 10 hrs 1 C 1.2 hrs 8.8 hrs 10 hrs C/1.5 1.8 hrs 8.2 hrs 10 hrs C/2 2.4 hrs 7.6 hrs 10 hrs C/2.5 3.5 hrs 6.5 hrs 10 hrs C/3 4.0 hrs 6.0 hrs 10 hrs C/4 4.6 hrs 5.4 hrs 10 hrs |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |