Back Button ADS5521IPAPR Datasheet HTML 21Page - Texas Instruments ADS5521IPAPR Datasheet HTML 22Page - Texas Instruments ADS5521IPAPR Datasheet HTML 23Page - Texas Instruments ADS5521IPAPR Datasheet HTML 24Page - Texas Instruments ADS5521IPAPR Datasheet HTML 25Page - Texas Instruments ADS5521IPAPR Datasheet HTML 26Page - Texas Instruments ADS5521IPAPR Datasheet HTML 27Page - Texas Instruments ADS5521IPAPR Datasheet HTML 28Page - Texas Instruments ADS5521IPAPR Datasheet HTML 29Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 25 / 36 page
background image
REFERENCE CIRCUIT
29
30
31
R EF P
R EF M
IR EF
1 W
1 W
56.2 kW
1 mF
1 mF
CLOCK INPUT
5 kW
5 kW
3 pF
3 pF
6 pF
CLKP
CLKM
CM
CM
ADS5521
www.ti.com ...................................................................................................................................................... SBAS309D – MAY 2004 – REVISED OCTOBER 2008
The ADS5521 has built-in internal reference generation, requiring no external circuitry on the printed circuit board
(PCB). For optimum performance, it is best to connect both REFP and REFM to ground with a 1-
µF decoupling
capacitor (the 1-
Ω resistor shown in Figure 44 is optional). In addition, an external 56.2-kΩ resistor should be
connected from IREF (pin 31) to AGND to set the proper current for the operation of the ADC, as shown in
Figure 44. No capacitor should be connected between pin 31 and ground; only the 56.2-k
Ω resistor should be
used.
Figure 44. REFP, REFM, and IREF Connections for Optimum Performance
The ADS5521 clock input can be driven with either a differential clock signal or a single-ended clock input, with
little or no difference in performance between both configurations. The common-mode voltage of the clock inputs
is set internally to CM (pin 17) using internal 5-k
Ω resistors that connect CLKP (pin 10) and CLKM (pin 11) to CM
(pin 17), as shown in Figure 45.
Figure 45. Clock Inputs
When driven with a single-ended CMOS clock input, it is best to connect CLKM (pin 11) to ground with a 0.01-
µF
capacitor, while CLKP is ac-coupled with a 0.01-
µF capacitor to the clock source, as shown in Figure 46.
Copyright © 2004–2008, Texas Instruments Incorporated
Submit Documentation Feedback
25
Product Folder Link(s): ADS5521



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com