17 / 24 page ![]() ADT7461 the ADT7461. A simple voltage comparator trips if the voltage at D+ exceeds VDD −1 V (typical), signifying an open circuit between D+ and D−. The output of this comparator is checked when a conversion is initiated. Bit 2 of the status register (OPEN flag) is set if a fault is detected. If the ALERT pin is enabled, setting this flag will cause ALERT to assert low. If the user does not wish to use an external sensor with the ADT7461, then in order to prevent the OPEN flag being set continuously, the user should tie the D+ and D− inputs of the ADT7461 together. Most temperature sensing diodes have an operating temperature range of −55°C to +150°C. Above 150°C, they lose their semicon- ductor characteristics and approximate conductors instead. This results in a diode short, setting the OPEN flag. The external diode in this case will no longer give an accurate temperature meas- urement. A read of the temperature result register will give the last good temperature measurement. The user should be aware that, while the diode fault is triggered, the temperature measure- ment on the external channel may not be accurate. THE ADT7461 INTERRUPT SYSTEM The ADT7461 has two interrupt outputs, ALERT and THERM. Both have different functions and behavior. ALERT is maskable and responds to violations of software-programmed tempera- ture limits or an open-circuit fault on the external diode. THERM is intended as a fail-safe interrupt output that cannot be masked. If the external or local temperature exceeds the programmed high temperature limits, or equals or exceeds the low tempera- ture limits, the ALERT output is asserted low. An open-circuit fault on the external diode also causes ALERT to assert. ALERT is reset when serviced by a master reading its device address, provided the error condition has gone away, and the status register has been reset. The THERM output asserts low if the external or local tempera- ture exceeds the programmed THERM limits. The THERM temperature limits should normally be equal to or greater than the high temperature limits. THERM is reset automatically when the temperature falls back within the THERM limit. The external THERM limit is set by default to 85°C, as is the local THERM limit. A hysteresis value can be programmed, in which case, THERM will reset when the temperature falls to the limit value minus the hysteresis value. This applies to both local and remote measurement channels. The power-on hysteresis default value is 10°C, but this may be reprogrammed to any value after power-up. The hysteresis loop on the THERM outputs is useful when THERM is used for on/off control of a fan. The user’s system can be set up so that when THERM asserts a fan can be switched on to cool the system. When THERM goes high again, the fan can be switched off. Programming a hysteresis value protects from fan jitter, where the temperature hovers around the THERM limit, and the fan is constantly being switched. Table 13. THERM Hysteresis THERM Hysteresis Binary Representation 0°C 0 000 0000 1°C 0 000 0001 10°C 0 000 1010 shows how the THERM and ALERT outputs operate. A user may wish to use the ALERT output as a SMBALERT to signal to the host via the SMBus that the temperature has risen. The user could use the THERM output to turn on a fan to cool the system, if the temperature continues to increase. This method would ensure that there is a fail-safe mechanism to cool the system, without the need for host intervention. Figure 19 Figure 19. Operation of the ALERT and THERM Interrupts Figure 19 1 3 2 4 THERM LIMIT HIGH TEMP LIMIT THERM LIMIT-HYSTERESIS RESET BY MASTER ALERT THERM 100 °C TEMPERATURE 90 °C 80 °C 70 °C 60 °C 50 °C 40 °C 1. If the measured temperature exceeds the high temperature limit, the ALERT output will assert low. 2. If the temperature continues to increase and exceeds the THERM limit, the THERM output asserts low. This can be used to throttle the CPU clock or switch on a fan. 3. The THERM output deasserts (goes high) when the temperature falls to THERM limit minus hysteresis. In , the default hysteresis value of 10°C is shown. 4. The ALERT output deasserts only when the temperature has fallen below the high temperature limit, and the master has read the device address and cleared the status register. Pin 6 on the ADT7461 can be configured as either an ALERT output or as an additional THERM output. THERM2 will assert low when the temperature exceeds the programmed local and/or remote high temperature limits. It is reset in the same manner as THERM, and it is not maskable. The programmed hysteresis value applies to THERM2 also. Rev. 0 | Page 17 of 24 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |