Back Button CPC7695BATR Datasheet HTML 16Page - IXYS Corporation CPC7695BATR Datasheet HTML 17Page - IXYS Corporation CPC7695BATR Datasheet HTML 18Page - IXYS Corporation CPC7695BATR Datasheet HTML 19Page - IXYS Corporation CPC7695BATR Datasheet HTML 20Page - IXYS Corporation CPC7695BATR Datasheet HTML 21Page - IXYS Corporation CPC7695BATR Datasheet HTML 22Page - IXYS Corporation CPC7695BATR Datasheet HTML 23Page - IXYS Corporation CPC7695BATR Datasheet HTML 24Page - IXYS Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 25 page
background image
INTEGRATED CIRCUITS DIVISION
CPC7695
20
www.ixysic.com
R01
2.7.3 Alternate Break-Before-Make Operation
The second break-before-make method is also
available for use with all versions of the CPC7695. As
shown in “Truth Table for CPC7695xA and CPC7695xB” on
page 15 and “Truth Table for CPC7695xC” on page 15,
when pulled to a logic low the bidirectional TSD
interface disables all of the CPC7695 switches.
Although logically disabled, an active (closed) ringing
switch (SW4) will remain closed until the next current
zero crossing event.
As shown in the table “Operation Logic Table (Ringing to
Talk Transition): Break-Before-Make” on page 19, this
operation is similar to the one shown in “Alternate
Operation Logic Table (Ringing to Talk Transition):
Break-Before-Make” on page 20, except in the method
used to select the All-Off state and when the
INRINGING, INTESTin and INTESTout inputs are
reconfigured for theTalk state.
1.
Pull TSD to a logic low to end the Ringing state.
This opens the ringing return switch (SW3) and
prevents any other switches from closing.
2.
Keep TSD low for at least one-half the duration of
the ringing cycle period to allow sufficient time for
a zero crossing current event to occur and for the
circuit to enter the break before make state.
3.
During the TSD low period, set the INRINGING,
INTESTin and INTESTout inputs to theTalk state
(0,0,0).
4.
Release TSD allowing the internal pull-up to
activate the break switches.
When using TSD as an input, the two recommended
states are “0,” which overrides the logic inputs while
forcing an All-Off state, and “Z,” which allows switch
control via the logic input pins. This requires the use of
an open-collector or open-drain type buffer.
Alternate Operation Logic Table (Ringing to Talk Transition): Break-Before-Make
2.8 Ringing Switch Zero-Cross Current Turn Off
After the application of a logic input to turn SW4 off,
the ringing switch is designed to delay the change in
state until the next zero-crossing. Once active, the
switch requires a zero-current crossing to turn off, and
therefore should not be used to switch a pure DC
signal. The switch will remain in the on state no matter
the logic input until the next zero crossing. These
switching characteristics will reduce and possibly
eliminate overall system impulse noise normally
associated with ringing switches. See IXYS Integrated
Circuits Division application note AN-144, Impulse Noise
Benefits of Line Card Access Switches for more
information. The attributes of ringing switch SW4 may
make it possible to eliminate the need for a zero-cross
switching scheme. A minimum impedance of 300
 in
series with the ringing generator is recommended.
2.9 Power Supplies
Both a +5V supply and battery voltage are connected
to the CPC7695. Switch state control is powered
exclusively by the +5V supply. As a result, the
CPC7695 exhibits extremely low power consumption
during active and idle states.
State
INRINGING INTESTin INTESTout Latch
TSD
Timing
Break
Switches
Ringing
Return
Switch
(SW3)
Ringing
Switch
(SW4)
Test
Switches
Ringing
1
0
0
0
Z
-
Off
On
On
Off
All-Off
1
0
1
X0
Hold this state for at least
one-half of ringing cycle. SW4
waiting for zero current to turn off.
Off
Off
On
Off
Break-
Before-
Make
00
0
Zero current has occurred. SW4
has opened
Off
Off
Off
Off
Talk
0
0
0
0
Z
Break switches close.
On
Off
Off
Off
* For the CPC7695xA/B versions the input pattern (1,1,1) may also be used for the All-Off state.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com