Back Button LMP93601 Datasheet HTML 17Page - Texas Instruments LMP93601 Datasheet HTML 18Page - Texas Instruments LMP93601 Datasheet HTML 19Page - Texas Instruments LMP93601 Datasheet HTML 20Page - Texas Instruments LMP93601 Datasheet HTML 21Page - Texas Instruments LMP93601 Datasheet HTML 22Page - Texas Instruments LMP93601 Datasheet HTML 23Page - Texas Instruments LMP93601 Datasheet HTML 24Page - Texas Instruments LMP93601 Datasheet HTML 25Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 44 page
background image
LMP93601
www.ti.com
SNAS633A – MARCH 2014 – REVISED SEPTEMBER 2014
Table 5. Wake Up Time From Low Power Modes (continued)
Mode
Registers
Power
Wake Up Time
Programmable via
Standby
Maintained
~175 µA
~100 µs to go to
SPI
conversion mode
Conversion
Maintained
1.1 mA
n/a
SPI
8.3.16 Power-On Sequence and Reset (POR) Function
An internal power on reset is generated after both the internal LDO (to supply the internal digital) and IOVDD
reach valid values. The internal LDO will reach stable values only after the AVDD has reached at least 2.7 V.
The device should be powered up with AVDD enabled and stabilized first, then the IOVDD. This allows the
device to start in the default power up state and ensures that the internal power on reset is generated after both
the internal LDO (to supply the internal digital) and IOVDD reach valid values. The internal LDO will reach stable
values only after the AVDD has reached at least 2.7 V for 1 ms. Alternatively, AVDD and IOVDD can be
connected together, but this can result in an erroneous brown-out condition being reported when the ramp time
of the supplies is slower than 0.1 V/ms. For example, if the AVDD = IOVDD are linearly ramped from 0 to 3.3 V
in longer than 330 µs, the brown could possibly trigger and be logged in the status register and the first
conversion result could read ‘7FFF’. To avoid this erroneous brown-out report, three alternative solutions are
available:
a. After the supplies are stable, reset the part (either with the RSTB pin or with a soft reset via SPI). After this
reset, the part can be programmed and used as intended.
b. Or, after the supplies are stable, program the part as desired, but before initiating the first conversion, read
back the status register(s) of the enabled channel(s) to clear the erroneous brown-out status.
c. Or, wait supplying the XCLK to the part until after the supplies are stable
8.3.17 Brown-Out Detection Function
A brown-out detection circuit monitors the AVDD. It triggers an alarm only when AVDD falls below ~2.55 V and
stays below 2.55 V for more than 16 fxclk cycles. The brown-out detection has a hysteresis of ~65 mV. The
alarm will result in “0x7FFF” data and the appropriate channel status register(s) can be read to decode the alarm.
The brown-out error function can be masked via SPI with the “alarm mask” register.
8.3.18 Reset Function
The device can be reset to the default (Standby) state via the SPI or taking the RSTB pin low. The reaction time
from the reset (either via SPI or RSTB pin) to the device getting to Standby mode is on the order of 100 µs. See
Table 6
8.4 Device Functional Modes
8.4.1 Single-Shot Mode
In Single Shot mode each conversion is triggered by a Start Trigger from the microcontroller unit (MCU) to the
LMP93601 by pulsing the SYNC pin or via a start SPI command (SYNC is recommended for exact timing
control). After the LOCK bit is set, the external µC should wait 3 XCLK cycles before it sends a start trigger. This
is to allow the internal synchronizer enough time to synchronize the SPI write of the LOCK bit into the XCLK
domain. This assumes the analog has already settled (otherwise, allow ~100 µs to go from standby to conversion
mode).
The SYNC has typical setup/hold time of 20 ns with respect to XCLK, as shown in Figure 19.
Copyright © 2014, Texas Instruments Incorporated
Submit Documentation Feedback
21
Product Folder Links: LMP93601



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com