Back Button TLK3101 Datasheet HTML 9Page - Texas Instruments TLK3101 Datasheet HTML 10Page - Texas Instruments TLK3101 Datasheet HTML 11Page - Texas Instruments TLK3101 Datasheet HTML 12Page - Texas Instruments TLK3101 Datasheet HTML 13Page - Texas Instruments TLK3101 Datasheet HTML 14Page - Texas Instruments TLK3101 Datasheet HTML 15Page - Texas Instruments TLK3101 Datasheet HTML 16Page - Texas Instruments TLK3101 Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 24 page
background image
TLK3101
2.5 Gbps to 3.125 Gbps TRANSCEIVER
SCAS649A – AUGUST 2000 – REVISED FEBRUARY 2001
13
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
Terminal Functions (Continued)
signal (continued)
TERMINAL
TYPE
DESCRIPTION
NAME
NO.
TYPE
DESCRIPTION
PREM
56
Input‡
Preemphasis control. Selects the amount of preemphasis to be added to the high speed data output drivers.
Left low or unconnected, 5% of pre-emphasis is added. Pulled high, 20% of preemphasis is added.
RX_ER/
PRBS_PASS
29
Output†
Receive error. When RX_ER and RX_DV/LOS are asserted, indicates that an error was detected
somewhere in the frame presently being output on the receive data bus. When RX_ER is asserted and
RX_DV/LOS is deasserted, indicates that carrier extension data is being presented. RX_ER goes to high
impedance state during power-on reset.
When PRBSEN= low (deasserted), this pin is used to indicate receive error (RX_ER). When PRBSEN = high
(asserted), this pin indicates status of the PRBS test results (high=pass).
RX_DV/
LOS
30
Output†
Receive data valid. RX_DV/LOS is output by the transceiver to indicate that recovered and decoded data is
being output on the receive data bus. RX_DV/LOS is asserted continuously from the first recovered word of
the frame through the final recovered word and is deasserted prior to the first rising edge of RX_CLK that
follows the final word. RX_DV/LOS is in high-impedance state during power-on reset.
If, during normal operation, the differential signal amplitude on the serial receive pins is below 200 mV,
RX_DV/LOS is asserted high along with RX_ER and the receive data bus to indicate a loss of signal
condition. If the device is in power-down mode, RX_DV/LOS is the output of the signal detect circuit and is
asserted low when a loss of signal condition is detected.
TX_EN
20
Input‡
Transmit enable. TX_EN in combination with TX_ER indicates the protocol device is presenting data on the
transmit data bus for transmission. TX_EN must be high with the first word of the preamble and remain
asserted while all words to be transmitted are presented on the transmit data bus. TX_EN must be negated
prior to the first rising edge of GTX_CLK following the final word of a frame.
TX_ER
22
Input‡
Transmit error coding. When TX_ER and TX_EN are high, indicates that the transceiver generates an error
somewhere in the frame presently being transferred. When TX_ER is asserted and TX_EN is deasserted,
indicates the protocol device is presenting carrier extension data. When TX_ER is deasserted with TX_EN
asserted, indicates that normal data is being presented.
† Hi-Z on power-up
‡ Internal pull-down
test
TERMINAL
TYPE
DESCRIPTION
NAME
NO.
TYPE
DESCRIPTION
ENABLE
24
Input§
Device enable. When this pin is held low, the device is placed in power-down mode. Only the signal detect
circuit on the serial receive pair is active. When asserted high, the transceiver goes into power-on reset
before beginning normal operation.
LOOPEN
21
Input‡
Loop enable. When LOOPEN is high, the internal loopback path is activated. The transmitted serial data is
directly routed internally to the inputs of the receiver. This provides a self-test capability in conjunction with
the protocol device. The DOUTTXP and DOUTTXN outputs are held in a high-impedance state during the
loopback test. LOOPEN is held low during standard operational state with external serial outputs and inputs
active.
PRBSEN
26
Input‡
PRBS test enable. When asserted high results of pseudorandom bit stream (PRBS) tests can be monitored
on the RX_ER/PRBS_PASS pin. A high on PRBS_PASS indicates that valid PRBS is being received.
TESTEN
27
Input‡
Test mode enable. This pin should be left unconnected or tied low.
‡ Internal pulldown
§ Internal pullup



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com