| Electronic Components Datasheet Search |
|
LP3921 Datasheet(PDF) 16 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LP3921 Datasheet(HTML) 16 Page - Texas Instruments |
|
16 / 41 page ![]() LDO2 - 7 PS_HOLD LDO1 If PS_HOLD is low 35 ms after initially going low, then LDO2-7 are shutdown LDO1 is shutdown 40 Ps after other LDO's are shutdown 35 ms 40 Ps RESET CHG_IN HF_PWR PS_HOLD LDO1 LDO2 320 ms 87% 87% Reg PS_HOLD needs to be asserted within 1200 ms after HF_PWR, or CHG_IN rising edge has been detected. If charger is connected (CHG_IN) or HF_PWR is applied, then both events are filtered for 320 ms before enabling LDO1 60 ms 1.2s If no enabling signal is high on the rising edge of PS_HOLD, shutdown will occur. RESET 200 Ps Either HF_PWR or CHG_IN will enable LDO1 LP3921 SNVS580A – AUGUST 2008 – REVISED MAY 2013 www.ti.com Figure 4. LP3921 Power On Behavior (Failed PS_Hold) Figure 5. LP3921 Normal Shutdown Behavior LP3921 Serial Port Communication Slave Address Code 7h’7E 16 Submit Documentation Feedback Copyright © 2008–2013, Texas Instruments Incorporated Product Folder Links: LP3921 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |