34
CAPACITORS
ALUMINIUM ELECTROLYTIC STANDARD RADIAL CEBM
SPECIFICATION
Item
Performance Characteristics
Operating Temperature Range
-40 to +85°C
-25 to +85°C
Rated Working Voltage Range
6.3 to 100V DC
160 to 450V DC
Nominal Capacitance Range
0.47 to 15000µF
0.47 to 220µF
Capacitance Tolerance
± 20% (120Hz, +20°C)
Leakage Current
l ≤ 0.01CV or 3[µA] after 2 minutes
l ≤ 0.06CV [µA] after 2 minutes
whichever is greater measured with
application of rated working voltage at +20°C
rated working voltage applied at +20°C
tan ∂
Working voltage [V]
6.3
10
16
25
35
50
63
100
tan ∂ (max.)
0.22
0.19
0.16
0.14
0.12
0.10
0.09
0.08
Working voltage [V]
160
200
250
400
450
tan ∂ (max.)
0.16
0.18
0.18
0.20
0.20
(120Hz,
r
o
F
)
C
°
0
2
+
capacitance value > 1000µF, add 0.02 per extra 1000µF
Ripple Current
Refer to standard products table (120Hz, +85°C)
Correction factor for frequency
Frequency [Hz]
50/60
120
1K
10K
Correction factor (Multiplier)
0.7
1
1.3
1.7
Low Temperature Characteristics
Impedance ratio max. at 120Hz
Working voltage [V]
6.3
10
16
25
35
50
63
100
-25°C/+20°C
4
3
2
2
2
2
2
2
-40°C/+20°C
8
6
4
4
3
3
3
3
Working voltage [V]
160
200
250
400
450
-25°C/+20°C
2
2
3
15
15
For capacitance value > 1000µF,
Add 0.5 per extra 1000µF for
.
C
°
5
2
+
/
C
°
5
2
-
Add 1.0 per extra 1000µF for
.
C
°
0
2
+
/
C
°
0
4
-
Impedance
m
u
m
ix
a
M
C-Z (rated cap-[µF] x Impedance [Ω]) value at 10KHz
Working voltage [V]
6.3
10
16
25
35
50
63
100
C-Z max. at +20°C
220
160
125
90
80
60
55
50
C-Z max. at -25°C
3000
1900
1300
800
650
560
500
450
Working voltage [V]
160
200
250
450
C-Z max. at +20°C
100
140
150
270
C-Z max. at -25°C
2400
2500
3100
12000
High Temperature Loading
Test conditions
Duration
2000 hours
Ambient temperature
+85°C
Applied voltage
Rated DC working voltage
Post test requirements at +20°C
Leakage current
≤ Initial specified value
Capacitance change
≤ ± 20% of initial measured value
tan ∂
≤ 150% of initial specified value
Shelf Life
Test conditions
Duration
500 hours
Ambient temperature
+85°C
Applied voltage
(None)
Post test requirements at +20°C.
Same limits for high temperature loading.
www.dubilier.co.uk



Html Pages

1 2 3


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com