LM63 Datasheet(PDF) 19 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM63 Datasheet(HTML) 19 Page - National Semiconductor (TI) |
|
19 / 28 page ![]() 2.0 LM63 Registers (Continued) Configuration Register ADDRESS Hex Read/ Write Bits POR Value Name Description 03 (09) HEX CONFIGURATION REGISTER 03 (09) R/W 70 ALERT Mask When this bit is a 0, ALERT interrupts are enabled. When this bit is set to a 1, ALERT interrupts are masked, and the ALERT pin is always in a high impedance (open) state. 6 0 STANDBY When this bit is a 0, the LM63 is in operational mode, converting, comparing, and updating the PWM output continuously. When this bit is a 1, the LM63 enters a low power standby mode. In STANDBY, continuous conversions are stopped, but a conversion/comparison cycle may be initiated by writing any value to register 0x0F. Operation of the PWM output in STANDBY depends on the setting of bit 5 in this register. 50 PWM Disable in STANDBY When this bit is a 0, the LM63’s PWM output continues to output the current fan control signal while in STANDBY. When this bit is a 1, the PWM output is disabled (as defined by the PWM polarity bit) while in STANDBY. 4:3 00 These bits are unused and always set to 0. 20 ALERT/Tach Select When this bit is a 0, the ALERT/Tach pin is an open drain ALERT output. When this bit is a 1, the ALERT/Tach pin is a high impedance Tachometer input. Note that if this bit is set, the function of the ALERT/Tach pin must be Tach input, so an external ALERT condition will not occur. 10 T_CRIT Limit Override The T_CRIT limit for the remote diode is nominally 85˚C. This value can be changed once after power-up by first setting this bit to a 1, then programming a new T_CRIT value into the Remote Diode T_CRIT Limit (register 0x19). The T_CRIT value can not be changed again except by cycling power to the LM63. 00 RDTS Fault Queue 0: an ALERT will be generated if any Remote Diode conversion result is above the Remote High Set Point or below the Remote Low Setpoint. 1: an ALERT will be generated only if three consecutive Remote Diode conversions are above the Remote High Set Point or below the Remote Low Setpoint. www.national.com 19 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |