Electronic Components Datasheet Search
  English  ▼

X  

ISO7810F Datasheet(PDF) 8 Page - Texas Instruments

Part # ISO7810F
Description  High-Performance, 8000-VPK Reinforced Single-Channel Digital Isolator
PDF  32 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI1 [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI1 - Texas Instruments

ISO7810F Datasheet(HTML) 8 Page - Texas Instruments

Back Button ISO7810F Datasheet HTML 4Page - Texas Instruments ISO7810F Datasheet HTML 5Page - Texas Instruments ISO7810F Datasheet HTML 6Page - Texas Instruments ISO7810F Datasheet HTML 7Page - Texas Instruments ISO7810F Datasheet HTML 8Page - Texas Instruments ISO7810F Datasheet HTML 9Page - Texas Instruments ISO7810F Datasheet HTML 10Page - Texas Instruments ISO7810F Datasheet HTML 11Page - Texas Instruments ISO7810F Datasheet HTML 12Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 32 page
background image
8
ISO7810, ISO7810F
SLLSEP1B – JULY 2015 – REVISED JUNE 2016
www.ti.com
Product Folder Links: ISO7810 ISO7810F
Submit Documentation Feedback
Copyright © 2015–2016, Texas Instruments Incorporated
6.7 Regulatory Information
DW package certifications are complete. DWW package certifications completed for UL, VDE, and TUV and planned for CSA
and CQC.
VDE
CSA
UL
CQC
TUV
Certified according to DIN V
VDE V 0884-10 (VDE V
0884-10):2006-12 and DIN
EN 60950-1 (VDE 0805 Teil
1):2011-01
Approved under CSA
Component Acceptance
Notice 5A, IEC 60950-1 and
IEC 60601-1
Recognized under UL 1577
Component Recognition
Program
Certified according to GB
4943.1-2011
Certified according to EN 61010-
1:2010 (3rd Ed) and EN 60950-
1:2006/A11:2009/A1:2010/A12:2011
/A2:2013
Reinforced insulation
Maximum transient isolation
voltage, 8000 VPK;
Maximum repetitive peak
isolation voltage, 2121
VPK(DW package), 2828 VPK
(DWW package);
Maximum surge isolation
voltage, 8000 VPK
Reinforced insulation per
CSA 60950-1-07+A1+A2
and IEC 60950-1 2nd Ed.,
800 VRMS max working
voltage (pollution degree 2,
material group I);
Single protection, 5700
VRMS
Reinforced Insulation,
Altitude
≤ 5000 m, Tropical
Climate, 250 VRMS maximum
working voltage
5700 VRMS Reinforced insulation per
EN 61010-1:2010 (3rd Ed) up to
working voltage of 600 VRMS (DW
package) and 1000 VRMS (DWW
package)
2 MOPP (Means of Patient
Protection) per CSA 60601-
1:14 and IEC 60601-1 Ed.
3.1,
250 VRMS (354 VPK) max
working voltage
5700 VRMS Reinforced insulation per
EN 60950-
1:2006/A11:2009/A1:2010/A12:2011
/A2:2013 up to working voltage of
800 VRMS (DW package) and 1450
VRMS (DWW package)
Certificate number:
40040142
Master contract number:
220991
File number: E181974
Certificate number:
CQC15001121716
Client ID number: 77311
6.8 Safety Limiting Values
Safety limiting intends to minimize potential damage to the isolation barrier upon failure of input or output circuitry. A failure of
the I/O can allow low resistance to ground or the supply and, without current limiting, dissipate sufficient power to overheat
the die and damage the isolation barrier potentially leading to secondary system failures.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
DW PACKAGE
IS
Safety input, output, or supply
current
RθJA = 89°C/W, VI = 5.5 V, TJ = 150°C, TA = 25°C, see Figure 3
255
mA
RθJA = 89°C/W, VI = 3.6 V, TJ = 150°C, TA = 25°C, see Figure 3
390
RθJA = 89°C/W, VI = 2.75 V, TJ = 150°C, TA = 25°C, see Figure 3
511
PS
Safety input, output, or total
power
RθJA = 89°C/W, TJ = 150°C, TA = 25°C, see Figure 5
1404
mW
TS
Maximum safety temperature
150
°C
DWW PACKAGE
IS
Safety input, output, or supply
current
RθJA = 92.2°C/W, VI = 5.5 V, TJ = 150°C, TA = 25°C, see Figure 4
246
mA
RθJA = 92.2°C/W, VI = 3.6 V, TJ = 150°C, TA = 25°C, see Figure 4
377
RθJA = 92.2°C/W, VI = 2.75 V, TJ = 150°C, TA = 25°C, see Figure 4
493
PS
Safety input, output, or total
power
RθJA = 92.2°C/W, TJ = 150°C, TA = 25°C, see Figure 6
1356
mW
TS
Maximum safety temperature
150
°C
The maximum safety temperature is the maximum junction temperature specified for the device. The power
dissipation and junction-to-air thermal impedance of the device installed in the application hardware determines
the junction temperature. The assumed junction-to-air thermal resistance in the Thermal Information is that of a
device installed on a high-K test board for leaded surface mount packages. The power is the recommended
maximum input voltage times the current. The junction temperature is then the ambient temperature plus the
power times the junction-to-air thermal resistance.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com