8 / 17 page ![]() OPA561 SBOS206E − DECEMBER 2001 − REVISED FEBRUARY 2007 www.ti.com 8 ENABLE/STATUS (E/S) PIN The Enable/Status Pin provides two unique functions: 1) output disable by forcing the pin LOW and 2) thermal shutdown indication by monitoring the voltage level at the pin. One or both of these functions can be utilized on the same device. For normal operation (output enabled), the E/S pin must be pulled HIGH (at least 2V above V−). A small value capacitor connected between the E/S pin and V− may be appropriate for noisy applications. To enable the OPA561 permanently, the E/S pin can be tied to V+ through a 402k Ω pull-up resistor. Output Disable The shutdown pin is referenced to the negative supply (V−). Therefore, shutdown operation is slightly different in single-supply and dual-supply applications. In single-supply operation, V− typically equals common ground. Therefore, the shutdown logic signal and the OPA561’s shutdown pin are referenced to the same potential. In this configuration, the logic pin and the OPA561 enable can simply be tied together. Shutdown occurs for voltage levels of < 0.8V. The OPA561 is enabled at logic levels > 2V. In dual-supply operation, the logic pin is still referenced to a logic ground. However, the shutdown pin of the OPA561 is still referenced to V−. To shutdown the OPA561, the voltage level of the logic signal needs to be level shifted using an optocoupler, as shown in Figure 3. Optocoupler 4N38 402k Ω NOTE: (1) Optional may be required to limit leakage current of octocoupler at high temperatures. E/S V+ (a) +5V (b) HCT or TTL In HCT or TTL In (a) (b) OPA561 (1) V − Figure 3. Shutdown Configuration for Dual Supplies To disable the output, the E/S pin is pulled LOW, no greater than 0.8V above V−. This function can be used to conserve power during idle periods. The typical time required to shut down the output is 50ns. To return the output to an enabled state, the E/S pin should be pulled to at least 2.0V above V−. Typically, the output is enabled within 3 µs. It should be noted that pulling the E/S pin HIGH (output enabled) does not disable the internal thermal shutdown. Ensuring Microcontroller Compatibility Not all microcontrollers output the same logic state after power-up or reset. 8051-type microcontrollers, for example, output logic HIGH levels on their ports while other models power up with logic LOW levels after reset. In configuration (a) as shown in Figure 3, the shutdown signal is applied on the cathode side of the photodiode within the optocoupler. A high logic level causes the OPA561 to be enabled, and a low logic level shuts the OPA561 down. In configuration (b) of Figure 3, with the logic signal applied on the anode side, a high level causes the OPA561 to shutdown and low level enables the op amp. OVER-CURRENT FLAG The OPA561 features an over-current status flag (CLS, Pin 9) that can be monitored to see if the load exceeds the current limit. The output signal of the over current limit flag is compatible to standard logic. The CLS signal is referenced to V−. A voltage level of less than (V−) + 0.8V indicates normal operation and a level of greater than (V−) + 2 indicates that the OPA561 is in current limit. The flag is HIGH as long as the output of the OPA561 is in current limit. At very low signal frequencies, typically < 1kHz, both the upper (sourcing current) and lower current limit (sinking current) are monitored. At frequencies > 1kHz, due to internal circuit limitations, the flag output signal for the upper current limit becomes delayed and shortened. The flag signal for the lower current limit is unaffected by this behavior. As the signal frequency increases further, only the lower current limit (sinking current) is output on pin 9. OUTPUT STAGE COMPENSATION The complex load impedances common in power op amp applications can cause output stage instability. For normal operation, output compensation circuitry is typically not required. However, if the OPA561 is intended to be driven into current limit, an R/C network (snubber) may be required. A snubber circuit may also enhance stability when driving large capacitive loads (> 1000pF) or inductive loads (motors, loads separated from the amplifier by long cables). Typically, 3 Ω to 10Ω in series with 0.01 µF to 0.1µF is adequate. Some variations in circuit value may be required with certain loads. Not Recommended for New Designs |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |