| Electronic Components Datasheet Search |
|
SLTS170C Datasheet(PDF) 6 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
SLTS170C Datasheet(HTML) 6 Page - Texas Instruments |
|
6 / 11 page ![]() Application Notes For technical support and more information, see inside back cover or visit www.ti.com PT4400/4410 Series Operating Features and System Considerations for the PT4400/PT4410 Series of DC/DC Converters Over-Current Protection To protect against load faults these converters incorporate output over-current protection. Applying a load to the output that exceeds the converter’s over-current threshold (see applicable specification) will cause the output voltage to momentarily fold back, and then shut down. Following shutdown the module will periodically attempt to auto- matically recover by initiating a soft-start power-up. This is often described as a “hiccup” mode of operation, whereby the module continues in the cycle of successive shutdown and power up until the load fault is removed. Once the fault is removed, the converter automatically recovers and returns to normal operation. Output Over-Voltage Protection Each converter incorporates protection circuitry that continually senses for an output overvoltage (OV) condi- tion. The O V threshold automatically tracks the VID output voltage program setting to a level that is 25 % higher than that programmed at the control pins, VID0 through VID4. If the converter output voltage exceeds this threshold, the converter is immediately shut down and remains in a latched-off state. To resume normal operation the converter must be actively reset. This can only be done by momentarily removing the input power to the converter. For failsafe operation and redundancy, the O V protection uses circuitry that is independent of the converter’s internal feedback loop. Over-Temperature Protection Over-temperature protection is provided by an internal temperature sensor, which closely monitors the tempera- ture of the converter’s metal case. If the case temperature exceeds a nominal 115 °C, the converter will shut down. The converter will then automatically restart when the sensed temperature drops back to approximately 105 °C. When operated outside its recommended thermal derating envelope (see data sheet SOA curves), the converter will typcially cycle on and off at intervals from a few seconds to one or two minutes. This is to ensure that the internal components are not permanently damaged from exces- sive thermal stress. Under-Voltage Lockout The Under-Voltage Lock-Out (UVLO) is designed to prevent the operation of the converter until the input voltage is close to the minimum input voltage. The converter is held off when the input voltage is below the UVLO threshold, and turns on when the input voltage rises above the threshold. This prevents high start-up current during normal power-up of the converter, and minimizes the current drain from the input source during low input voltage conditions. The converter will meet full specifications when the minimum specified input voltage is reached. The UVLO circuitry also overrides the operation of the Remote On/Off control. Only when the input voltage is above the UVLO threshold will the Remote On/Off control be functional. Primary-Secondary Isolation These converters incorporate electrical isolation between the input terminals (primary) and the output terminals (secondary). All converters are production tested to a withstand voltage of 1500VDC. This specification com- plies with UL60950 and EN60950 and the requirements for operational isolation. This allows the converter to be configured for either a positive or negative input voltage source. The data sheet ‘Pin Descriptions’ section provides guidance as to the correct reference that must be used for the external control signals. Input Current Limiting The converter is not internally fused. For safety and overall system protection, the maximum input current to the converter must be limited. Active or passive current limiting can be used. Passive current limiting can be a fast acting fuse. A 125-V fuse, rated no more than 10 A, is recommended. Active current limiting can be imple- mented with a current limited “Hot-Swap” controller. Thermal Considerations Airflow may be necessary to ensure that the module can supply the desired load current in environments with elevated ambient temperatures. The required airflow rate may be determined from the Safe Operating Area (SOA) thermal derating chart (see converter specifica- tions). The recommended direction for airflow is into, or perpendicular to, the longest side of the module’s metal case. See Figure 1. Recommended direction for airflow is into (perpendicular to) the longest side. Figure 1 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |