| Electronic Components Datasheet Search |
|
CS10.481 Datasheet(PDF) 18 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
CS10.481 Datasheet(HTML) 18 Page - Red Lion Controls. Inc |
|
18 / 20 page ![]() CS10.481 C–Series 48V, 5A, SINGLE PHASE INPUT Nov. 2006 / Rev.1.1 DS-CS10.481-EN All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 18/20 25.5. INDUCTIVE AND CAPACITIVE LOADS The unit is designed to supply any kind of load, including unlimited capacitive and inductive loads. 25.6. SERIES OPERATION The power supply can be put in series to increase the output voltage. Fig. 25-5 Schematic for series operation Instructions for use in series: Earth Unit A AC DC Unit B AC DC - + - + Load + - a) It is possible to connect as many units in series as needed, providing the sum of the output voltage does not exceed 150Vdc. b) Voltages with a potential above 60Vdc are not SELV any more and can be dangerous. Such voltages must be installed with a protection against touching. c) For serial operation use power supplies of the same type. d) Earthing of the output is required when the sum of the output voltage is above 60Vdc. e) Keep an installation clearance of 15mm (left/right) between two power supplies and avoid installing the power supplies on top of each other. Note: Avoid return voltage (e.g. from a decelerating motor or battery) which is applied to the output terminals. 25.7. PARALLEL USE TO INCREASE OUTPUT POWER The power supply shall not be used in parallel to increase the output power. 25.8. PARALLEL USE FOR 1+1 REDUNDANCY Power supplies can be paralleled for 1+1 redundancy to gain a higher system availability. Redundant systems require a certain amount of extra power to support the load in case one power supply unit fails. The simplest way is to put two C-Series power supplies in parallel. In case one power supply unit fails, the other one is automatically able to support the load current without any interruption. This simple way to build a redundant system has two major disadvantages: - The faulty power supply can not be recognized. The green LED will still be on since it is reverse-powered from the other power supply. - It does not cover failures such as an internal short circuit in the secondary side of the power supply. In such a - virtually nearly impossible - case, the defective unit becomes a load for the other power supplies and the output voltage can not be maintained any more. This can only be avoided by utilizing decoupling diodes which are included in the decoupling module YR2.DIODE or redundancy module YRM2.DIODE. Recommendations for building redundant power systems: a) Use separate input fuses for each power supply. b) Monitor the individual power supply units. A DC-ok lamp and a DC-ok contact is included in the redundancy module YRM2.DIODE. This feature reports a faulty unit. c) When possible, connect each power supply to different phases or circuits. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |