| Electronic Components Datasheet Search |
|
LM2574 Datasheet(PDF) 18 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
LM2574 Datasheet(HTML) 18 Page - ON Semiconductor |
|
18 / 26 page ![]() LM2574, NCV2574 www.onsemi.com 18 Since the current rating of the LM2574 is only 0.5 A, the total package power dissipation for this switcher is quite low, ranging from approximately 0.1 W up to 0.75 W under varying conditions. In a carefully engineered printed circuit board, the through−hole DIP package can easily dissipate up to 0.75 W, even at ambient temperatures of 60 °C, and still keep the maximum junction temperature below 125 °C. Thermal Analysis and Design The following procedure must be performed to determine the operating junction temperature. First determine: 1. PD(max) − maximum regulator power dissipation in the application. 2. TA(max) − maximum ambient temperature in the application. 3. TJ(max) − maximum allowed junction temperature (125 °C for the LM2574). For a conservative design, the maximum junction temperature should not exceed 110 °C to assure safe operation. For every additional +10 °C temperature rise that the junction must withstand, the estimated operating lifetime of the component is halved. 4. RqJC − package thermal resistance junction−case. 5. RqJA − package thermal resistance junction−ambient. (Refer to Absolute Maximum Ratings on page 2 of this data sheet or RqJC and RqJA values). The following formula is to calculate the approximate total power dissipated by the LM2574: PD = (Vin x IQ) + d x ILoad x Vsat where d is the duty cycle and for buck converter d + ton T + V O V in , IQ (quiescent current) and Vsat can be found in the LM2574 data sheet, Vin is minimum input voltage applied, VO is the regulator output voltage, ILoad is the load current. D1 MBR150 L1 68 mH Output 7 1 Feedback 8.0 to 25 V Unregulated DC Input Cin 22 mF 5 3 4ON/OFF Pwr Gnd +Vin -12 V @ 100 mA Regulated Output Cout 680 mF LM2574−12 2 Sig Gnd Figure 27. Inverting Buck−Boost Develops −12 V (6) (12) (4) (5) (3) (14) The dynamic switching losses during turn−on and turn−off can be neglected if a proper type catch diode is used. The junction temperature can be determined by the following expression: TJ = (RqJA)(PD) + TA where (RqJA)(PD) represents the junction temperature rise caused by the dissipated power and TA is the maximum ambient temperature. Some Aspects That can Influence Thermal Design It should be noted that the package thermal resistance and the junction temperature rise numbers are all approximate, and there are many factors that will affect these numbers, such as PC board size, shape, thickness, physical position, location, board temperature, as well as whether the surrounding air is moving or still. At higher power levels the thermal resistance decreases due to the increased air current activity. Other factors are trace width, total printed circuit copper area, copper thickness, single− or double−sided, multilayer board, the amount of solder on the board or even color of the traces. The size, quantity and spacing of other components on the board can also influence its effectiveness to dissipate the heat. Some of them, like the catch diode or the inductor will generate some additional heat. ADDITIONAL APPLICATIONS Inverting Regulator An inverting buck−boost regulator using the LM2574−12 is shown in Figure 27. This circuit converts a positive input voltage to a negative output voltage with a common ground by bootstrapping the regulators ground to the negative output voltage. By grounding the feedback pin, the regulator senses the inverted output voltage and regulates it. In this example the LM2574−12 is used to generate a −12 V output. The maximum input voltage in this case cannot exceed 28 V because the maximum voltage appearing across the regulator is the absolute sum of the input and output voltages and this must be limited to a maximum of 40 V. This circuit configuration is able to deliver approximately 0.1 A to the output when the input voltage is 8.0 V or higher. At lighter loads the minimum input voltage required drops to approximately 4.7 V, because the buck−boost regulator topology can produce an output voltage that, in its absolute value, is either greater or less than the input voltage. Since the switch currents in this buck−boost configuration are higher than in the standard buck converter topology, the available output current is lower. This type of buck−boost inverting regulator can also require a larger amount of startup input current, even for light loads. This may overload an input power source with a current limit less than 0.6 A. Because of the relatively high startup currents required by this inverting regulator topology, the use of a delayed startup or an undervoltage lockout circuit is recommended. While using a delayed startup arrangement, the input capacitor can charge up to a higher voltage before the switch−mode regulator begins to operate. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |