  MAXREFDES112B Datasheet HTML 1Page - Maxim Integrated Products MAXREFDES112B Datasheet HTML 2Page - Maxim Integrated Products MAXREFDES112B Datasheet HTML 3Page - Maxim Integrated Products MAXREFDES112B Datasheet HTML 4Page - Maxim Integrated Products MAXREFDES112B Datasheet HTML 5Page - Maxim Integrated Products MAXREFDES112B Datasheet HTML 6Page - Maxim Integrated Products MAXREFDES112B Datasheet HTML 7Page - Maxim Integrated Products MAXREFDES112B Datasheet HTML 8Page - Maxim Integrated Products MAXREFDES112B Datasheet HTML 9Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 15 page
background image
The MAX17596 is a peak-current-mode controller for design of wide input-voltage flyback
and boost regulators. The reference design operates over a 17V to 36V input voltage
range, and provides up to 800mA (plus 20% overhead) at 12V output. The MAX17596 has
an internal amplifier with 1% accurate reference, eliminating the need for an external
reference. The switching frequency is programmable from 100kHz to 1MHz with an
accuracy of 8%, allowing optimization of magnetic and filter components, resulting in
compact and cost-effective power conversion. This design is set to switch at 500kHz. For
EMI-sensitive applications, the MAX17596 incorporates a programmable frequency
dithering scheme, enabling low-EMI spread-spectrum operation.
The input undervoltage lockout (EN/UVLO) is provided for programming the input-supply
start voltage (set to 17V in the design), and to ensure proper operation during brownout
conditions. The EN/UVLO input is also used to turn on/off the IC. The overvoltage input
(OVI) protection scheme is provided to make sure that the controller shuts down when the
input supply exceeds its maximum allowed value (set to 36V in the design).
A capacitor is connected to the SS pin to program the soft-start period hence reduces the
input inrush current during startup. Hiccup-mode overcurrent protection and thermal
shutdown are provided to minimize dissipation in overcurrent and overtemperature fault
conditions.
The reference design delivers a peak efficiency of 88% with the supplied components
when the input is 24V. This general-purpose power solution can be used in many different
types of power applications, such as programmable logic controllers (PLC), industrial
process control, industrial sensors, telecom power supplies, isolated battery chargers,
servers, and embedded computing.
System Diagram



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com