  CAT4016 Datasheet HTML 1Page - ON Semiconductor CAT4016 Datasheet HTML 2Page - ON Semiconductor CAT4016 Datasheet HTML 3Page - ON Semiconductor CAT4016 Datasheet HTML 4Page - ON Semiconductor CAT4016 Datasheet HTML 5Page - ON Semiconductor CAT4016 Datasheet HTML 6Page - ON Semiconductor CAT4016 Datasheet HTML 7Page - ON Semiconductor CAT4016 Datasheet HTML 8Page - ON Semiconductor CAT4016 Datasheet HTML 9Page - ON Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 14 page
background image
CAT4016, CAV4016
www.onsemi.com
2
PIN CONNECTIONS
24−Lead SOIC (W), TSSOP (Y)
1
GND
SIN
CLK
LED1
LATCH
VDD
RSET
SOUT
BLANK
LED16
LED15
LED14
LED13
LED2
LED3
LED4
LED12
LED11
LED10
LED9
LED5
LED6
LED7
LED8
24−Lead TQFN (HV6)
LED14
LED13
LED12
LED11
LED10
LED9
GND
SIN
CLK
LED1
LATCH
LED2
1
Figure 1. Typical Application Circuit
LED1
VDD
VIN
3 V to
5.5 V
1
mF
20 mA
3 k
W
BLANK
LATCH
SIN
CLK
LED2
GND
CAT4016
LED16
SOUT
to next
device
RSET
Table 1. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Unit
VDD Supply Voltage
6
V
Logic input/output voltage (SIN, SOUT, CLK, BLANK, LATCH)
−0.3 V to VDD+0.3 V
V
LEDn voltage
6
V
DC output current on LED1 to LED16
150
mA
Storage Temperature Range
−55 to +160
_C
Junction Temperature Range
−40 to +150
_C
Lead Soldering Temperature (10 sec.)
300
_C
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
Table 2. RECOMMENDED OPERATING CONDITIONS
Parameter
Range
Unit
VDD
3.0 to 5.5
V
Voltage applied to LED1 to LED16
0.4 to 5.5
V
LED current RSET control range
up to 100
mA
Ambient Temperature Range
CAT4016
CAV4016*
−40 to +85
−40 to +125
_C
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
*Product under development.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com