123 / 476 page ![]() TC290 / TC297 / TC298 / TC299 BB-Step Package and Pinning DefinitionsTC299x Pin Definition and Functions: Data Sheet 2-117 V 1.1 2015-05 LVDSM = Pad class LVDSM (5V/3.3V) LVDSH = Pad class LVDSH (3.3V) S = Pad class S (Class S parameters for digital input and class D parameters for analog input function) D = Pad class D (VADC / DSADC) PU = with pull-up device connected during reset (PORST = 0) PU1 = with pull-up device connected during reset (PORST = 0)1) 2) 3) PD = with pull-down device connected during reset (PORST = 0) PD1 = with pull-down device connected during reset (PORST = 0)1) 2) 3) PX = Behavior depends on usage: PD in EVR13 SMPS Mode and PU1 in GPIO Mode OD = open drain during reset (PORST = 0) HighZ = tri-state during reset (PORST = 0) PORST = PORST input pad XTAL1 = XTAL1 input pad XTAL2 = XTAL2 input pad VGATE1P = VGATE1P VGATE3P = VGATE3P Vx = Supply NC = These pins are reserved for future extensions and shall not be connected externally NC1 = These pins are not connected on package level and will not be used for future extensions NCVDDPSB = This pin has a different functionality in an Production Device and an Emulation Device. For details pls. see Pin/Ball description of this pin. NCVDDSB = This pin has a different functionality in an Production Device and an Emulation Device. For details pls. see Pin/Ball description of this pin. 2.1.2 Emergency Stop Function The Emergency Stop function can be used to force GPIOs (General Purpose Inputs/Outputs) via an external input signal (EMGSTOPA or EMGSTOPB) into a defined state: • Input state and • PU or High-Z depending on HWCFG[6] level latched during Porst active Control of the Emergency Stop function: • The Emergency Stop function can be enabled/disabled in the SCU (see chapter “SCU”, “Emergency Stop Control”) • The Emergency Stop input signal, EMGSTOPA (P33.8) / EMGSTOPB (P21.2) , can selected in the SCU (see chapter “SCU”, “Emergency Stop Control”) • On port level, each GPIO can be enabled/disabled for the Emergency Stop function via the Px_ESR (Port x Emergency Stop) registers in the port control logic (see chapter “General Purpose I/O Ports and Peripheral I/O Lines”, “Emergency Stop Register”). The Emergency Stop function is available for all GPIO Ports with the following exceptions: • Not available for P20.2 (General Purpose Input/GPI only, overlayed with Testmode) • Not available for P40.x (analoge input ANx overlayed with GPI) • Not available for P32.0 EVR13 SMPS mode. 1) The default state of GPIOs (Px.y) during and after PORST active is controllled via HWCFG[6] (P14.4). HWCFG[6] has a weak internal pull-up active at start-up if the pin is left unconnected.See also User´s Manual, “Introduction Chapter”, “General Purpose I/O Ports and Peripheral I/O Lines”, Figure: “Default state of port pins during and after reset”. 2) If HWCFG[6] is left unconnected or is externally pulled high, weak internal pull-ups (PU1) / pull-downs (PD1) are active during and after reset. 3) If HWCFG[6] is connected to ground, the PD1 / PU1 pins are predominantly in HighZ during and after reset. TC290/TC297/TC298/TC299 BB-Step Data Sheet downloaded by saravanakumar maniyam (larsen and Toubro limited) at 08 Sep 2015 08:06 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |