| Electronic Components Datasheet Search |
|
TC290 Datasheet(PDF) 124 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TC290 Datasheet(HTML) 124 Page - Infineon Technologies AG |
|
124 / 476 page ![]() TC290 / TC297 / TC298 / TC299 BB-Step Package and Pinning DefinitionsTC299x Pin Definition and Functions: Data Sheet 2-118 V 1.1 2015-05 • Not available for dedicated I/O without General Purpose Output function (e.g ESRx, TMS, TCK) The Emergency Stop function can be overruled on the following GPIO Ports: • P00.x and P02.x: Emergency Stop can be overruled by the 8-Bit Standby Controller (SBR), if implemented. Overruling can be disabled via the control registers P00_SCR / P02_SCR (see chapter “General Purpose I/O Ports and Peripheral I/O Lines”, P00 / P01) • P00.x: Emergency Stop can be overruled by the VADC. Overruling can be disabled via the control register P00_SCR (see chapter “General Purpose I/O Ports and Peripheral I/O Lines”, P00) • P14.0 and P14.1: Emergency Stop can be overruled in the DXCPL mode (DAP over can physical layer mode). No Overruling in the DXCM (Debug over can message) mode • P21.6: Emergency Stop can be overruled in JTAG mode if this pin is used as TDI • P21.7: Emergency Stop can be overruled in JTAG or Three Pin DAP mode • P20.0: Emergency Stop can be overruled in JTAG mode if this GPIO is used as TDI • P33.8: Emergency Stop can be overruled if this pin is used as safety output pin (SMUFSP) 2.1.3 Pull-Up/Pull-Down Reset Behavior of the Pins In case of leakage test (PORST = 0 and TESTMODE = 0), the pull-down of the TRST pin is switched off. In case of an user application (TESTMODE = 1), the pull-down of the TRST is always switched on. Table 2-26 List of Pull-Up/Pull-Down Reset Behavior of the Pins Pins PORST = 0 PORST = 1 all GPIOs Pull-up if HWCFG[6] = 1 or High-Z if HWCFG[6] = 0 TDI, TESTMODE Pull-up PORST1) 1) Pull-down with IPORST relevant is always activated when a primary supply monitor detects a violation. Pull-down with IPORST relevant Pull-down with IPDLI relevant TRST, TCK, TMS Pull-down ESR0 The open-drain driver is used to drive low.2) 2) Valid additionally after deactivation of PORST until the internal reset phase has finished. See the SCU chapter for details. Pull-up3) 3) See the SCU_IOCR register description. ESR1 Pull-up3) TDO Pull-up High-Z/Pull-up4) 4) Depends on JTAG/DAP selection with TRST. TC290/TC297/TC298/TC299 BB-Step Data Sheet downloaded by saravanakumar maniyam (larsen and Toubro limited) at 08 Sep 2015 08:06 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |