| Electronic Components Datasheet Search |
|
ADUX1020 Datasheet(PDF) 17 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADUX1020 Datasheet(HTML) 17 Page - Analog Devices |
|
17 / 32 page ![]() ADUX1020 Data Sheet Rev. A | Page 16 of 31 Use the following steps to calibrate the 32 kHz clock by referencing the timer of the controlling microprocessor. Do not set the I2C output rate to a speed that overloads the I2C FIFO. If the micro- processor is fully available for handling clock calibration operation at this time, and its I2C speed is set to 400 kHz, the I2C throughput will be more than 2 kHz. 1. Set the projected output rate to 820 Hz by writing 0x1C to Register 0x44. 2. Set up and run the device in sample mode by writing 0x8 to Register 0x45, Bits[3:0]. 3. Flush the I2C FIFO by writing Register 0x49, Bit 15. 4. Poll data from I2C FIFO for 0.5 sec by repeatedly reading Register 0x60. Count the number of sample sets for 1 sec. 5. Calculate the actual output rate equal to the sample set count divided by 0.5. 6. Adjust the 32 kHz oscillator trim value by writing to Register 0x18, Bits[3:0] with the appropriate value. 7. Repeat Step 1 through Step 5 until the actual measured output data rate is as close to 820 Hz as possible. If the output data rate is below 820 Hz, increment the trim value, and if it is above 820 Hz, decrement the trim value. Calibrating the 32 MHz Clock The 32 MHz oscillator on the ADUX1020 may also have up to 30% variation in frequency due to the variation of on-chip RC components. Use the following steps to calibrate the 32 MHz clock by comparing it with the 32 kHz clock. 1. Enable the 32 kHz oscillator by writing Register 0x18, Bit 7. 2. Enable the 32 MHz oscillator by writing Register 0x32, Bit 3 and Bit 11. 3. Enable clock calibration by writing Register 0x30, Bit 5. 4. Read the calibration result from Register 0x0A, Bits[11:0]. 5. Compare the calibration result. The calibration is complete when the result read is as close as possible to the optimal value of 2000. If it is not, increment the trim value if the result is below 2000, or decrement if it is above 2000. Write the new trim value and then write 1 to Register 0x30, Bit 5. Note that typically two trim values produce calibration results that straddle the optimal result. Choose the closest. 6. Write the new trim value in Register 0x1A, Bits[7:0]. 7. Disable calibration by writing 0 to Register 0x30, Bit 5. READING DATA The ADUX1020 provides multiple methods for accessing the sample data. Interrupt signaling is available to simplify timely data access. The FIFO is available to loosen the system timing requirements for data accesses. Reading Data Using the FIFO The ADUX1020 includes a 64-byte FIFO memory buffer that can store data from either sample/gesture mode or proximity mode. Register 0x45, Bits[7:4] select the kind of data to be written to the FIFO. Data packets are written to the FIFO at the output data rate. Output Data Rate = fSAMPLE/N where: fSAMPLE is the sampling frequency. N is the averaging factor for sample/gesture mode or proximity mode. A data packet for the FIFO consists of a complete sample for either proximity mode or sample/gesture mode. In proximity mode, the device can store either only intensity i data as 2 bytes or x, y, and i data as 6 bytes. In sample/gesture mode, the device always sends 4 bytes to the FIFO. To ensure that data packets are intact, new data is written only to the FIFO if there is sufficient space for a complete packet. Any new data that arrives when there is not enough space is lost. The FIFO continues to store data when sufficient space exists. Always read FIFO data in complete packets to ensure that data packets remain intact. The number of bytes currently stored in the FIFO is available in Register 0x49, Bits[14:8]. A dedicated FIFO interrupt is also available and automatically generates when a specified amount of data is written to the FIFO. To read data from the FIFO using an interrupt-based method, use the following procedure: 1. In standby mode, set the configuration of sample/gesture or proximity mode as desired for operation. 2. Write to Register 0x45, Bits[7:4] with the desired data format for each mode. 3. Set FIFO_TH in Register 0x1F, Bits[11:8] to the interrupt threshold. A good value for this is the number of 16-bit words in a data packet minus 1, which causes an interrupt to generate when at least one complete packet is in the FIFO. 4. Enable the FIFO interrupt by writing INT_MASK, Register 0x48, Bits[7:0]. Also, configure the interrupt pin (INT) by writing the appropriate value to Register 0x1C, Bit 2. 5. Enter sample/gesture or proximity mode by setting Register 0x45, Bits[3:0] to the desired value. 6. When an interrupt occurs, the following results: a. Note that there is no requirement to read the FIFO_ STATUS register because the interrupt is generated only if there is one or more full packets. Optionally, the interrupt routine can check for the presence of more than one available packet by reading this register. b. Force the 32 MHz clock on by writing 0x0F4F to Register 0x32. c. Read a complete packet using one or more multiword accesses using Register 0x60. Reading the FIFO automatically frees the space for new samples. d. Set the 32 MHz clock to be controlled by the internal state machine by writing 0x40 to Register 0x32. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |