4 / 5 page ![]() MBR350, MBR360 Bulletin PD-20594 rev. B 03/03 4 www.irf.com Fig. 6 - Max. Non-Repetitive Surge Current Fig. 5- Forward Power Loss Characteristics (2) Formula used: T C = T J - (Pd + Pd REV ) x R thJC ; Pd = Forward Power Loss = I F(AV) x V FM @ (I F(AV) / D) (see Fig. 6); Pd REV = Inverse Power Loss = V R1 x I R (1 - D); I R @ V R1 = 80% rated V R Fig. 4 - Max. Allowable Lead Temperature Vs. Average Forward Current Average Forward Current - I F(AV) (A) Average Forward Current - I F(AV) (A) Square Wave Pulse Duration - t p (microsec) 0 0.5 1 1.5 2 2.5 3 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 DC RMS Limit D = 0.20 D = 0.25 D = 0.33 D = 0.50 D = 0.75 DC 10 100 1000 10 100 1000 10000 At Any Rated Load Condition And With rated Vrrm Applied Following Surge 0 20 40 60 80 100 120 140 160 012345 DC Square wave (D = 0.50) 80% Rated Vr applied see note (2) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|