Back Button PM5347S Datasheet HTML 39Page - PMC-Sierra, Inc PM5347S Datasheet HTML 40Page - PMC-Sierra, Inc PM5347S Datasheet HTML 41Page - PMC-Sierra, Inc PM5347S Datasheet HTML 42Page - PMC-Sierra, Inc PM5347S Datasheet HTML 43Page - PMC-Sierra, Inc PM5347S Datasheet HTML 44Page - PMC-Sierra, Inc PM5347S Datasheet HTML 45Page - PMC-Sierra, Inc PM5347S Datasheet HTML 46Page - PMC-Sierra, Inc PM5347S Datasheet HTML 47Page - PMC-Sierra, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 43 / 302 page
background image
PM5347 S/UNI-PLUS
DATA SHEET
PMC-941033
ISSUE 6
SATURN USER NETWORK INTERFACE PLUS
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
27
Pin Name
Type
Pin
No.
Function
TSOC
Input
69
The transmit start of cell (TSOC) signal marks the
start of cell on the TDAT[15:0] bus. When TSOC is
high, the first word of the cell structure is present
on the TDAT[15:0] bus. It is not necessary for
TSOC to be present at each cell. An interrupt
may be generated if TSOC is high during any
word other than the first word of the cell structure.
TSOC is sampled on the rising edge of TFCLK
and is considered valid only when TWRENB is
simultaneously asserted.
TCA
Output
70
The transmit cell available (TCA) signal indicates
when a cell is available in the transmit FIFO.
When asserted, TCA indicates that the transmit
FIFO is not full. When TCA is deasserted, it
indicates that either the transmit FIFO is near full
and can accept no more than four writes or that
the transmit FIFO is full (as selected in the TACP
FIFO Control register) In addition, to reduce FIFO
latency, the FIFO full level can be programmed in
the TACP FIFO Control register. The default state
of TCA can be selected in the S/UNI-PLUS
Master Control register. TCA is updated on the
rising edge of TFCLK. The active polarity of this
signal is programmable and defaults to active
high.
XOFF
Input
71
The transmit off (XOFF) input prevents the
insertion of cells from the transmit FIFO. If XOFF
is set high, the next cell transmitted is an
idle/unassigned cell regardless of the number of
cells in the FIFO. Idle/unassigned cells are
transmitted until XOFF is deasserted. XOFF may
be treated as an asynchronous signal. XOFF
must be tied low if it is not used.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com