| Electronic Components Datasheet Search |
|
89U Datasheet(PDF) 3 Page - TE Connectivity Ltd |
|
|
|||||||||||||||||||||||||||||
89U Datasheet(HTML) 3 Page - TE Connectivity Ltd |
|
3 / 7 page ![]() 89 Uncompensated SENSOR SOLUTIONS ///89U 2/2016 Page 3 PERFORMANCE SPECIFICATIONS Supply Current: 1.5 mA Ambient Temperature: 25°C (unless otherwise specified) PARAMETERS MIN TYP MAX UNITS NOTES Sensitivity 15 22 28 mV/V@FS Zero Pressure Output -4 4 mV/V Pressure Non Linearity -0.25 0.25 %Span 1 Pressure Hysteresis ±0.05 %Span Repeatability ±0.02 %Span Input/Output Resistance 3900 4500 5100 Ω 2 Temperature Coefficient – Resistance 1300 1510 1750 ppm/°C 3 Temperature Coefficient – Sensitivity -1450 -1250 -1000 ppm/°C 3 Temperature Coefficient – Offset 2 uV/V/ºC 3 Thermal Hysteresis – Span ±0.05 %Span 3 Thermal Hysteresis – Offset ±0.05 %Span 3 Long Term Stability – Span ±0.1 %Span 4 Long Term Stability – Offset ±0.1 %Span 4 Supply Current 0.5 1.5 2.0 mA Supply Voltage 9.5 V Insulation Resistance (50Vdc) 50 MΩ 5 Pressure Overload 3X Rated 6 Pressure Burst 4X Rated 7 Operating Temperature -40 +125 ºC Storage Temperature -50 +125 ºC Torque 154 180 In-lb 8 Weight 9 grams Media – Pressure Port Liquids and Gases compatible with 316/316L Stainless Steel Notes 1. Measured at ambient temperature. 2. Best fit straight line. 3. Measured with both -E pins shorted together. 4. Over the temperature range -20°C to +85°C with respect to 25°C. 5. Minimum resistance between case and pins. 6. 3X or 20,000psi, whichever is less. The maximum pressure that can be applied without changing the transducer’s performance or accuracy. 7. 4X or 30,000psi, whichever is less. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer. 8. For devices without fittings, typical receptacle is 316 ST STL, tensile strength 75,000psi min. 9. Direct mechanical contact with diaphragm is prohibited. Diaphragm surface must remain free of defects (scratches, punctures, fingerprints, etc.) for device to operate properly. Caution is advised when handling parts with exposed diaphragms. Use protective cap whenever devices are not in use. Remarks 10. Testing: All 03k, 05k and 10kpsi parts are tested at 2500psi. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |