13 / 21 page ![]() MS5541-30C Miniature 14 bar Module SENSOR SOLUTIONS ///MS5541C 09/2015 Page 13 SECOND-ORDER TEMPERATURE COMPENSATION In order to obtain full temperature accuracy over the whole temperature range, it is recommended to compensate for the non-linearity of the output of the temperature sensor. This can be achieved by correcting the calculated temperature and pressure by a second order correction factor. The second-order factors are calculated as follows: Fig. 5: Flow chart for calculating the temperature and pressure to the optimum accuracy. High Temperatures dT2 = dT – (dT/128*dT/128)/8 dT < 0 yes Calculate temperature TEMP = (200 + dT2*(C6+100)/2 11) (0.1°C) Low Temperatures dT2 = dT – (dT/128*dT/128)/2 dT 0 yes |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|