Electronic Components Datasheet Search
  English  ▼

X  

PKB4000 Datasheet(PDF) 2 Page - Ericsson

Part # PKB4000
Description  DC/DC converters, Input 36-75 V, Output 30 A/90 W
PDF  46 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  ERICSSON [Ericsson]
Direct Link  http://www.ericsson.com
Logo ERICSSON - Ericsson

PKB4000 Datasheet(HTML) 2 Page - Ericsson

  PKB4000 Datasheet HTML 1Page - Ericsson PKB4000 Datasheet HTML 2Page - Ericsson PKB4000 Datasheet HTML 3Page - Ericsson PKB4000 Datasheet HTML 4Page - Ericsson PKB4000 Datasheet HTML 5Page - Ericsson PKB4000 Datasheet HTML 6Page - Ericsson PKB4000 Datasheet HTML 7Page - Ericsson PKB4000 Datasheet HTML 8Page - Ericsson PKB4000 Datasheet HTML 9Page - Ericsson Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 46 page
background image
Ericsson Internal
PRODUCT SPECIFICATION
2 (4)
Prepared (also subject responsible if other)
No.
EZHIXZH
1/1301-BMR 636 Uen
Approved
Checked
Date
Rev
Reference
SEC/D (Julia You)
MICJOHN
2011-02-24
C
General Information
Ordering Information
See Contents for individual product ordering numbers.
Option
Suffix
Ordering No.
Isolated Surface mount
Positive Remote Control Logic
Increased stand-off height
Lead length 3.69 mm (0.145 in)
Lead length 4.57 mm (0.180 in)
SI
P
M
LA
LB
PKB 4711 SINB
PKB 4711 PIPNB
PKB 4711 PINBM
PKB 4711 PINBLA
PKB 4711 PINBLB
Note : As an example a positive logic, increased standoff, short pin product
would be PKB 4711 PIPNBMLA.
Reliability
The failure rate (
λ) and mean time between failures (MTBF=
1/
λ) is calculated at max output power and an operating
ambient temperature (T
A) of +40°C. Ericsson Power
Modules uses Telcordia SR-332 Issue 2 Method 1 to
calculate the mean steady-state failure rate and standard
deviation (
σ).
Telcordia SR-332 Issue 2 also provides techniques to
estimate the upper confidence levels of failure rates based
on the mean and standard deviation.
Mean steady-state failure rate,
λ
Std. deviation,
σ
214 nFailures/h
34.5 nFailures/h
MTBF (mean value) for the PKB series = 4.7 Mh.
MTBF at 90% confidence level = 3.9 Mh
Compatibility with RoHS requirements
The products are compatible with the relevant clauses and
requirements of the RoHS directive 2002/95/EC and have
a maximum concentration value of 0.1% by weight in
homogeneous materials for lead, mercury, hexavalent
chromium, PBB and PBDE and of 0.01% by weight in
homogeneous materials for cadmium.
Exemptions in the RoHS directive utilized in Ericsson
Power Modules products are found in the Statement of
Compliance document.
Ericsson Power Modules fulfills and will continuously fulfill
all its obligations under regulation (EC) No 1907/2006
concerning the registration, evaluation, authorization and
restriction of chemicals (REACH) as they enter into force
and is through product materials declarations preparing for
the obligations to communicate information on substances
in the products.
Quality Statement
The products are designed and manufactured in an
industrial environment where quality systems and methods
like ISO 9000, Six Sigma, and SPC are intensively in use to
boost the continuous improvements strategy. Infant
mortality or early failures in the products are screened out
and they are subjected to an ATE-based final test.
Conservative design rules, design reviews and product
qualifications, plus the high competence of an engaged
work force, contribute to the high quality of the products.
Warranty
Warranty period and conditions are defined in Ericsson
Power Modules General Terms and Conditions of Sale.
Limitation of Liability
Ericsson Power Modules does not make any other
warranties, expressed or implied including any warranty of
merchantability or fitness for a particular purpose
(including, but not limited to, use in life support
applications, where malfunctions of product can cause
injury to a person’s health or life).
© Ericsson AB 2013
The information and specifications in this technical
specification is believed to be correct at the time of
publication. However, no liability is accepted for
inaccuracies, printing errors or for any consequences
thereof. Ericsson AB reserves the right to change the
contents of this technical specification at any time without
prior notice.
E
PKB 4000 series
DC/DC converters, Input 36-75 V, Output 30 A/90 W
EN/LZT 146 394 R5D October 2013
© Ericsson AB
Technical Specification
2



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com