| Electronic Components Datasheet Search |
|
MCP9600 Datasheet(PDF) 34 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP9600 Datasheet(HTML) 34 Page - Microchip Technology |
|
34 / 50 page ![]() MCP9600 DS20005426B-page 34 2015-2016 Microchip Technology Inc. 5.3.3 ALERT CONFIGURATION REGISTERS This device integrates four individually-controlled temperature Alert Outputs. Each output is configured for the corresponding alert output using the Alert Out- put configuration registers. The configuration registers are used to enable each output, select the alert function mode as Comparator or Interrupt mode, Active-High or Active-Low output, detect rising or falling temperatures, and detect TH or TC temperature registers. The Comparator mode is useful for thermostat-type applications, such as on/off switches for fan controllers, buzzer or LED indicators. The Alert output asserts and deasserts when the temperature exceeds the user-specified limit and the user-specified hysteresis limit. The Interrupt mode is useful for interrupt driven microcontroller-based systems. The Alert Outputs are asserted each time the temperature exceeds the user specified Alert limit and Hysteresis limits. The microcontroller will have acknowledged the interrupt signal from the corresponding alert output by clearing the interrupt using bit 7 of the corresponding configuration register. The Rise/Fall bit (bit 3) and the temperature selection bit (bit 4) can be used to detect and maintain the Thermocouple temperature or the Cold-Junction temperature to the desired temperature window. TABLE 5-6: ALERT CONFIG. REGISTERS Register Register Pointer Alert 1 Configuration 0000 1000 Alert 2 Configuration 0000 1001 Alert 3 Configuration 0000 1010 Alert 4 Configuration 0000 1011 REGISTER 5-11: ALERT 1, 2, 3 AND 4 CONFIGURATION REGISTER R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R-0 R-0 R-0 Interrupt Clear — — Monitor TH/TC Rise/Fall Active Hi/Lo Comp/Int. Alert Enable bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’ -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bit 7 Interrupt Clear: 1 = Clears Interrupt flag (forced ‘0’ by device) 0 = Normal State or Cleared State bit 6-5 Unimplemented: Read as ‘0’ bit 4 Monitor TH or TC: 1 = Alert Monitor for TC Cold-Junction Sensor 0 = Alert Monitor for TH Thermocouple Temperature bit 3 Alert Temperature Direction, Rise/Fall: 1 = Alert Limit for Rising or Heating Temperatures 0 = Alert Limit for Falling or Cooling Temperatures bit 2 Alert State: 1 =Active High 0 = Active Low bit 1 Alert Mode: 1 = Interrupt Mode: Interrupt Clear bit (bit 7) must be set to deassert the alert output 0 = Comparator Mode bit 0 Alert Enable: 1 = Alert Output is Enabled 0 = Alert Output is Disabled |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |