Description  Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools.
PDF  6 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MACOM [Tyco Electronics]
Direct Link  http://www.macom.com
Logo MACOM - Tyco Electronics

1752680-2 Datasheet(HTML) 4 Page - Tyco Electronics

  1752680-2 Datasheet HTML 1Page - Tyco Electronics 1752680-2 Datasheet HTML 2Page - Tyco Electronics 1752680-2 Datasheet HTML 3Page - Tyco Electronics 1752680-2 Datasheet HTML 4Page - Tyco Electronics 1752680-2 Datasheet HTML 5Page - Tyco Electronics 1752680-2 Datasheet HTML 6Page - Tyco Electronics  
Zoom Inzoom in Zoom Outzoom out
 4 / 6 page
background image
408-8908
4 of 6
Rev A
5.2. Daily Maintenance
It is recommended that each operator of the dies be
made aware of, and responsible for, the following
steps of daily maintenance.
1. Remove dust, moisture, and other contaminants
from the dies with a clean brush, or a clean, soft,
lint-free cloth. Do NOT use objects that could
damage the dies.
2. If dies are coated with oil or preservative, wipe
clean - particularly in the crimping areas - before
placing them in use.
3. When dies are not in use, make certain all
surfaces are protected with a THIN coat of any good
SAE No. 20 motor oil, and mate and store them in a
clean, dry area.
5.3. Periodic Inspection
Regular inspections should be performed by quality
control personnel. A record of scheduled inspections
should remain with the dies or be made available to
supervisory personnel responsible for the the dies.
Though recommendations call for at least a monthly
inspection, the inspection frequency should be based
upon the amount of use, working conditions, operator
training and skill, and established company standards.
These inspections should be performed in the
following sequence:
A. Visual Inspection (Figure 6)
1. Remove all lubrication and accumulated film by
immersing the dies in a suitable degreaser that will
not affect paint or plastic material.
flattened, chipped, cracked, worn, or broken are
2. Check all surfaces for wear. Inspect the crimp
area for flattened, chipped, cracked, worn, or
broken areas. See Figure 6. If damage is evident,
the die must be replaced.
B. Gaging the Crimping Chamber (Figure 7 and Figure 8)
This inspection requires the use of a plug gage
conforming to the dimensions in Figure 7. Tyco
Electronics does not manufacture or market these
gages.
Proceed as follows:
1. Mate the dies until it is evident that they have
bottomed. Hold the dies in this position
2. Align the GO element with the wire barrel
crimping chamber. Push the element straight into
the crimping chamber without using force. The GO
element must pass completely through the crimping
chamber.
.
Figure 5



Html Pages

1 2 3 4 5 6


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com