| Electronic Components Datasheet Search |
|
ESS30-S Datasheet(PDF) 2 Page - ETAL Group |
|
|
|||||||||||||||||||||||||||||
ESS30-S Datasheet(HTML) 2 Page - ETAL Group |
|
2 / 6 page ![]() Electronic circuit breaker ESS30-Sxxx-DC24V Electronic circuit breaker ESS30-Sxxx-DC24V www.e-t-a.de 2 1617 4 Technical data (Tamb = 25 °C, UB = DC 24 V) Error message: Signal output F potential-free signal contact switches simultaneously with physical isolation, max. DC 30 V / 2 A, min. DC 12 V / 10 mA Signal output ESS30-S003 blue push button is in ON position: Signal change over contact signal contact 13-14 is closed 13-12 is open blue push button is in OFF position: signal contact 13-14 is open 13-12 is closed Visual status indication LED green UB is applied and switch S1 is ON and no overload, no short circuit OFF condition LED off l device switched off (switch S1 is OFF) l load circuit physically isolated l no operating voltage UB LED orange overload conditions > 1.2 times rated current until, electronic disconnection LED red electronic disconnection upon overload, short circuit or undervoltage General data Fail-safe element back-up fuse for ESS30-S.. not required due to integral redundant fail-safe element (protective element) Blade terminals 6.3 mm to EN 60934-6.3-0.8 Housing material moulded Mounting pluggable into power distribution systems for side-by-side mounting (module 17plus or 18plus by E-T-A) Ambient temperature 0...+60 °C (without condensation, cf. EN 60204-1) Storage temperature -40...+70 °C Humidity 96 hours at 95 % RH, 40 °C to IEC 60068-2-78,-Cab climate class 3K3 to EN60721 Vibration 3 g test to IEC 60068-2-6, test Fc Degree of protection operating area IP30 EN 60529 installation area IP00 EN 60529 EMC requirements noise emission: EN 61000-6-3 (EMC directive, CE logo) susceptibility: EN 61000-6-2 Insulation co-ordination 0.5 kV / pollution degree 2 (IEC 60934) reinforced insulation in operating area Dielectric strength (see also dimensions) operating area test voltage AC 1000 V installation area test voltage AC 500 V load circuit auxiliary contact test voltage AC 500 V Insulation resistance > 100 MΩ (DC 500 V) between (OFF condition) LINE (+) and LOAD (+) Dimensions (w x h x d) 12.5 x 78.5 x 60 mm (tolerances to DIN ISO 286 part 1 IT13) Operating force ON 5...8 N OFF 7...10 N Mass approx. 39 g Ttype ESS30 Electronic circuit breaker with current limitation Mounting S Version 0 with physical isolation in the event of a failure Signal input 0 without signal input Signal output: 3 double auxiliary change over contact (min. 12 V/10 mA; max. 30 V/2 A) Operating voltage DC 24 V voltage rating DC 24 V Current ratings 0.5 A 1 A 2 A 3 A 3.6 A 4 A 6 A 8 A 10 A ESS30 - S 0 0 3 - DC 24 V - 6 A ordering example Order numbering code Notes l The user has to ensure that the cable cross section of the load circuit in question complies with the current rating of the ESS30-S used. l In addition special precautions must be taken in the system or machine (e.g. use of a safety PLC) which reliably prevent an automatic re-start of parts of the system (cf. Machinery Directive 2006/42/EG and EN 60204-1, Safety of Machinery). In the event of a failure (short circuit/overload) the load circuit will be discon- nected electronically with physical isolation of the contacts by the ESS30-S. Approvals of ESS30-S Approval authority Standard Rated voltage Current ratings VDE EN 60934 DC 24 V 0.5 A…10 A UL UL 1077 DC 24 V 0.5 A…10 A |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |