2 / 2 page ![]() Input Input voltage AC 100-240V (Wide Range), 47...63 Hz Admiss. limits: AC 85...264V (DC 85...375V) Input current <0.6A (@ AC 100V, 30W Pout) <0.25A (@ AC 240V, 30W Pout) External fusing not required, unit provides internal fuse (T3A15H, not accessible) Transient immunity Transient resistance acc. to VDE 0160 / W2 (750V / 1.3ms), over entire load range Hold-up time (see diagram below) >170ms @ AC 230V, 10V / 3A >100ms @ AC 196V, 10V / 3A >18ms @ AC 100V, 10V / 3A Efficiency, Reliability Efficiency Losses typ. 84% (AC 230V, 10V / 3A) (see also diagram below) typ. 5.8W (AC 230V, 10V / 3A) MTBF (Reliability) appr. 650.000h acc. to Siemensnorm SN 29500 (10V / 3A, AC 230V, Tamb = +40°C) Prior to shipment, every unit undergoes the following tests in order to isolate any defective units which might suffer an early failure: • Run-in / burn-in (Full load, Tamb = +60°C, on/off cycle) • Functional test (100%) Construction, Mechanics, Installation Robust plastic housing (US Patent No. D442, 923S), fine ventilation grid on three housing sides to keep out small parts (e.g. screws), IP20 Dimensions and weight • W x H x D •Weight 45mm x 75mm x 91mm (+ DIN Rail)) 250g Mounting orientation , or (cf. ’Output’) Ventilation/Cooling • Free space f. cooling Normal convection, no fan required recom’d.: 25mm on sides with ventilation grid Easy snap-on mounting onto the DIN Rail (TS35/7,5 or TS35/15). Unit sits safely and firmly on the rail; no tools required even to remove Connection by Spring Clamp terminals; uniformly firm hold, vibration-resistant and maintenance-free. Connector size range • flexible cable • solid cable • Wire strip length 0.3-2.5mm2 (28-12 AWG) 0.3-4mm2 (28-12 AWG) Ferrules admissible 6mm (0.24in) recommended Design details – for your advantage: • All terminals are easy to reach as mounted on the front panel. • Input and output are strictly apart from each other (input below, out- put above) and so cannot be mixed up. • Mounting and connection do not require any screwdriver → Easy, quick, durable and reliable installation. • A jumper (output terminal) serves to adjust the output voltage (10V resp. 12V). Diagrams 0 20 40 60 80 100 120 90 125 160 195 230 Input voltage V ACin [V] Pout=30W, typ. Pout=30W, min. Pout=15W, typ. Pout=15W, min. 0 5 10 15 20 25 30 35 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] Output characteristic Vout/Iout (min.) Efficiency Hold-up time with ACin (@ Vout = 10V, typ.) (at Vout = 10V, typ. + min.) 0 2 4 6 8 10 12 14 0 1 2 3 456 Output current Iout [A] 230VAC 100-120VAC Vout range Mounting 85-150 V ACin A-a A-b A-c 150-264 V ACin A-a A-a A-b 100-375 V DCin A-a A-a A-b 85-100 V DCin B-b B-b B-c a b B A c 50 55 60 65 70 75 80 85 90 0,3 0,6 0,9 1,2 1,5 1,8 2,1 2,4 2,7 3 3,3 Output current Iout [A] 120 V ACin 230 V ACin Output Output voltage • preset without jumper: DC 10-12V (adj. by front panel potentiometer, adj. range guaranteed); with jumper: 12V ±0.5%, without jumper: 10V ±0.5% Voltage regulation stat. <1% @ Vout = 10V stat. <1.2% @ Vout = 12V, dyn. ±2.5% Vout over all Ripple Noise (Spikes) <2mVPP (200kHz bandw., 50 Ω measurem.) <10mVPP (20MHz bandw., 50 Ω measurem.) Overvoltage prot. (OVP) <18V Rated continuous loading at convection cooling: max. Iout = 3A @ Vout = 10V, max. Iout = 2.5A @ Vout = 12V, details see derating diagram below • power reserve 25%–40% (depending on Vin); details see diagr. 'output characteristic' below Overload behaviour Straight V/I characteristic (depending on Vin); details see diagr. 'output characteristic' below Protection Unit is protected against (also permanent) short-circuit, overload and open-circuit. Derating depending on built-in orientation; see diagram below Power back immunity 30V Operating indicator Green LED (DC ON) Environmental Data, EMC, Safety Ambient temperature range (measured 25mm below unit) • storage/transport • operation -25°C ... +85°C -10°C ... +70°C (for derating see diagram below) Humidity max. 95% (without condensation) Electromagnetic emissions (EME) EN 61000-6-3 (includes EN 61000-6-4) Class B (EN 55011, EN 55022) Electromagnetic immunity (EMI) EN 61000-6-2 (includes EN 61000-6-1) Safe low voltage: Prot. class/degree: SELV (EN60950, VDE0100/T.410), PELV (EN50178) Class I (EN60950) / IP20 (EN60529) The PSU complies with all major safety approvals for EU (EN 60950, EN 60204-1, EN 50178), USA (UL 60950, E137006, UL508 LISTED, E198865), Canada (CAN/CSA-C22.2 No 60950 [CUR],CAN/CSA-C22.2 No. 14 [CUL]), CB Scheme (IEC 60950). NEC Class 2 Power Supply and Hazardous Locati- on Class I Div. 2 (UL 1604) Technical Data ML30.102 Product information (ML30e102), Rev.: 29. June 2004. Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They are subject to change without prior notice. PULS GmbH, Arabellastraße 15, D-81925 München Tel: +49.(0)89.9278-244, Fax: +49.(0)89.9278-299, E-Mail: sales@puls-power.com www.puls-power.com Spri ng C lam ps Derating of output power |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |