| Electronic Components Datasheet Search |
|
ML50.102 Datasheet(PDF) 2 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
ML50.102 Datasheet(HTML) 2 Page - PULS GmbH |
|
2 / 2 page ![]() Input Input voltage AC 100-240V (Wide Range), 47...63Hz Admiss. limits: AC 85...264V (DC 85...375V) Input current <1.0A (@ AC 100V, 50W Pout) <0.6A (@ AC 196V, 50W Pout) External fusing not required, unit provides internal fuse (T3A15H, not accessible) Transient immunity Transient resistance acc. to VDE 0160 / W2 (750V / 1.3ms), over entire load range Hold-up time (see diagram below) >170ms @ AC 230V, 12V / 4.2A >97ms @ AC 196V, 12V / 4.2A >17ms @ AC 100V, 12V / 4.2A Efficiency, Reliability Efficiency Losses typ. 90% (AC 230V, 12V / 4.2A) (see also diagram below) typ. 6W (AC 230V, 12V / 4.2A) MTBF (Reliability) appr. 600.000h acc. to Siemensnorm SN29500 (12V / 4.2A, AC 230V, Tamb = +40°C) Prior to shipment, every unit undergoes the following tests in order to isolate any defective units which might suffer an early failure: • Run-in / burn-in (Full load, Tamb = +60°C, on/off cycle) • Functional test (100%) Construction, Mechanics, Installation Robust plastic housing (US Patent No. D442, 923S), fine ventilation grid on three housing sides to keep out small parts (e.g. screws), IP20 Dimensions and weight • W x H x D •Weight 45mm x 75mm x 91mm (+ DIN Rail)) 260g Mounting orientation , or (cf. ’Output’) Ventilation/Cooling • Free space f. cooling Normal convection, no fan required recom’d.: 25mm on sides with ventilation grid Easy snap-on mounting onto the DIN-rail (TS35/7,5 or TS35/15). Unit sits safely and firmly on the rail; no tools required even to remove Connection by Spring Clamp terminals; uniformly firm hold, vibration-resistant and maintenance-free. Connector size range • flexible cable • solid cable • Wire strip length 0.3-2.5mm2 (28-12 AWG) 0.3-4mm2 (28-12 AWG) Ferrules admissible 6mm (0.24in) recommended Design details – for your advantage: • All terminals are easy to reach as mounted on the front panel. • Input and output are strictly apart from each other (input below, out- put above) and so cannot be mixed up. • Mounting and connection do not require any screwdriver • A jumper (output terminal) serves to adjust the output voltage (12V resp. 15V). Diagrams 0 2 4 6 8 10 12 14 16 0 123 456 Output current Iout [A] Output characteristic Vout/Iout (typ.) Efficiency Hold-up time with ACin (@ Vout = 12V, typ.) (at Vout = 12V, typ. and min.) 100 V ACin 230 V ACin Vout range 60 65 70 75 80 85 90 95 0,2 0,6 1 1,4 1,8 2,2 2,6 3 3,4 3,8 4,2 Output current Iout [A] 100 V ACin 230 V ACin 0 10 20 30 40 50 60 -10 0 10 20 30 40 50 60 70 Ambient temperature [ °C] a b Mounting 85-150 V ACin A-a A-a A-c 150-264 V ACin A-a A-a A-b 100-375 V DCin A-a A-a A-b 85 V DCin A-b B-b B-c A B c 0 20 40 60 80 100 120 85 105 125 145 165 185 205 225 Input voltage V ACin [V] 50W typ. 50W min. 25W typ. 25W min. Output Output voltage • preset without jumper: DC 12-15V (adj. by front panel potentiometer, adj. range guaranteed); with jumper: 15V ± 3.5%, without jumper: 12V ± 0.5% Voltage regulation stat. <1% @ Vout = 12V stat. < 1.5% @ Vout = 15V, dyn. ±3% Vout over all Ripple/Noise <100mVPP (20MHz bandw., 50 Ω measurem.) Overvoltage prot. (OVP) <20V Rated continuous loading at convection cooling: max. Iout = 4.2A @ Vout = 12V, max. Iout = 3.4A @ Vout = 15V, details see derating diagram below • power reserve max. 10%(depending on Vin); details see diagr. 'output characteristic' below Overload behaviour Straight V/I characteristic (depending on Vin); details see diagr. 'output characteristic' below Protection Unit is protected against (also permanent) short- circuit, overload and open-circuit. Derating depending on built-in orientation; see diagram below Power back immunity 22V Operating indicator Green LED (DC ON) Environmental Data, EMC, Safety Ambient temperature range (measured 25 mm below unit) • storage/transport • operation -25°C ... +85°C -10°C ... +70°C (for derating see diagram below) Humidity max. 95% (without condensation) Electromagnetic emissions (EME) EN 61000-6-3 (includes EN 61000-6-4) Class B (EN 55011, EN 55022) Electromagnetic immunity (EMI) EN 61000-6-2 (includes EN 61000-6-1) Safe low voltage: Prot. class/degree: SELV (EN 60950, VDE0100/T.410), PELV (EN 50178) Class I (EN 60950) / IP20 (EN 60529) The PSU complies with all major safety approvals for EU (EN 60 950, EN 60204-1, EN 50178), USA (UL 60950, E137006, UL508 LISTED, E198865), Canada (CAN/CSA-C22.2 No 60950 [CUR],CAN/CSA-C22.2 No. 14 [CUL]), CB Scheme (IEC 60950). NEC Class 2 Power Supply and Hazardous Location Class I Div. 2 (UL 1604) Technical Data ML50.102 Product information (ML50e102), Rev.: 26. October 2007. Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They are subject to change without prior notice. PULS GmbH, Arabellastraße 15, D-81925 München Tel: +49.(0)89.9278-244, Fax: +49.(0)89.9278-299, E-Mail: sales@puls-power.com www.puls-power.com Spri ng C lam ps Derating of output power |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |