10 / 16 page ![]() 1.0 Functional Description (Continued) 1.3 SMBus INTERFACE The LM84 operates as a slave on the SMBus, so the SMBCLK line is an input (no clock is generated by the LM84) and the SMBData line is bi-directional. According to SMBus specifications, the LM84 has a 7-bit slave address. Bit 4 (A3) of the slave address is hard wired inside the LM84 to a 1. The remainder of the address bits are controlled by the address select pins ADD1 and ADD0, and are set by con- necting these pins to ground for a low, (0) , to V CC for a high, (1), or left floating (TRI-LEVEL). Therefore, the complete slave address is: A6 A5 A4 A3 A2 A1 A0 MSB LSB and is selected as follows: Address Select Pin State LM84 SMBus Slave Address ADD0 ADD1 A6:A0 binary 0 0 001 1000 0 TRI-LEVEL 001 1001 0 1 001 1010 TRI-LEVEL 0 010 1001 TRI-LEVEL TRI-LEVEL 010 1010 TRI-LEVEL 1 010 1011 1 0 100 1100 1 TRI-LEVEL 100 1101 1 1 100 1110 The LM84 latches the state of the address select pins during the first read or write on the SMBus. Changing the state of the address select pins after the first read or write to any device on the SMBus will not change the slave address of the LM84. 1.4 TEMPERATURE DATA FORMAT Temperature data can be read from the Local Temperature, Remote Temperature, and T_CRIT setpoint registers. Tem- perature data can only be written to the T_CRIT setpoint registers. Temperature data is represented by an 8-bit, two’s complement byte with an LSB (Least Significant Bit) equal to 1˚C: Temperature Digital Output Binary Hex +125˚C 0111 1101 7Dh +25˚C 0001 1001 19h +1˚C 0000 0001 01h 0˚C 0000 0000 00h −1˚C 1111 1111 FFh −25˚C 1110 0111 E7h −55˚C 1100 1001 C9h 1.5 OPEN-DRAIN OUTPUTS SMBData and T_CRIT_A outputs are open-drain and do not have internal pull-ups. A “high” level will not be observed on these pins until pull-up current is provided from some exter- nal source, typically a pull-up resistor. Choice of resistor value depends on many system factors but, in general, the pull-up resistor should be as large as possible. This will minimize any local temperature reading errors due to self heating of the LM84. The maximum resistance of the pull-up, based on LM84 specification for High Level Output Current, to provide a 2V high level, is 30 k Ω. 1.6 DIODE FAULT DETECTION Before each remote conversion the LM84 goes through an external diode fault detection sequence. If the D+ input is shorted to V CC or floating then the temperature reading will be +127˚C, bit 2 (OPEN) of the Status Register will be set. If the Remote T_CRIT setpoint is set to less than +127˚C then bit 4 (RTCRIT) of the Status Register will be set which will activate the T_CRIT_A output, if enabled. If D+ is shorted to GND or D−, the temperature reading will be 0˚C and bit 2 of the Status Register will not be set. www.national.com 10 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |