5 / 18 page ![]() NOTE: ANY COPY OF THIS DOCUMENT THAT DOES NOT HAVE A RED "CONTROL" STAMP IS AN UNCONTROLLED COPY. SPECIFICATION 55A, ISSUE 4 Page 5 of 18 3.5.4 Identification of Product When specified by the procuring activity, finished wire or cable shall be identified by a marking applied to the outer surface. The identification shall consist of the appropriate mark as specified by contract or the applicable specification sheet. The mark color shall be in accordance with MIL-STD-104, Class 1, and shall be contrasting to that of the marking surface. Identification shall be applied with the vertical axis of the printed characters parallel to the longitudinal axis of the wire or cable when the nominal diameter of the marking surface is 0.050 inch (1.27 mm) or smaller. The vertical axis of the printed characters may be either perpendicular or parallel to the longitudinal axis of the wire or cable when the nominal diameter of the marking surface exceeds 0.050 inch (1.27 mm). 3.5.5 Immersion When finished wire is tested in accordance with MIL-W-22759/32, the diameter increase shall be not more than 5 percent and there shall be no cracking of the insulation and no dielectric breakdown. 3.5.6 Insulation Flaws One hundred percent of finished wire and unshielded, unjacketed cable shall pass the impulse dielectric test or the spark test of MIL-W-22759 using the voltage specified in the applicable specification sheet. The test shall be performed during the final winding of the wire or cable on shipment spools or reels. 3.5.7 Jacket Concentricity When finished cable is tested in accordance with 4.6.8, the jacket concentricity shall be 70 percent, minimum. 3.5.8 Jacket Flaws One hundred percent of finished shielded and jacketed cable shall pass the jacket flaws test in accordance with 4.6.9 using the voltage specified in the applicable specification sheet. 3.5.9 Wrap Test When tested in accordance with 4.6.14, no cracking of the insulation is allowed. If the specification sheet does not specify a temperature, the test shall be performed at room temperature. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |