| Electronic Components Datasheet Search |
|
DLCD0001 Datasheet(PDF) 2 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
DLCD0001 Datasheet(HTML) 2 Page - Red Lion Controls. Inc |
|
2 / 8 page ![]() 2 BITS REGISTER NAME MODBUS REGISTER CH. A CH. B 15 Not Used - - 14 Not Used - - 13 Not Used - - 12 Not Used - - 11 Not Used - - 10 Not Used - - 9 Not Used - - 8 Not Used - - 7 Not Used - - 6 Not Used - - 5 Not Used - - 4 Not Used - - 3 Parameter Read Strobe (See Note 3) - - 2 Configuration Read Strobe (See Note 3) - - 1 Parameter Write Strobe (See Note 3) - - 0 Configuration Write Strobe (See Note 3) - - Table 4 - Control Block for Nx:3 and Nx:7 Flags Table 6 - Status Block for Nx:10 and Nx:14 Flags Table 7 - Status Block for Nx:11 and Nx:15 Flags Table 7 0 1 2 3 6 7 15 15 Table 6 0 1 2 3 4 7..5 15..8 14 40021 Output Power Channel B 13 40017 Process Value Channel B 12 Table 7 0 1 2 3 6 7 15 11 Table 6 0 1 2 3 4 7..5 15..8 10 40005 Output Power Channel A 9 40001 Process Value Channel A 8 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Nx: REFERENCE/ MODBUS REGISTER BIT POSITION Table 5 - Status Block - Channel A and B BITS REGISTER NAME MODBUS REGISTER CH. A CH. B 15..8 Input Error Status Register 40504 40504 7..5 Auto-Tune Phase 40012 40028 4 Control Output OP2 40016 40032 3 Control Output OP1 40014 40030 2 Set Point Ramping In Progress 40043 40051 1 Alarm Output AL2 40016 40032 0 Alarm Output AL1 40015 40031 BITS REGISTER NAME MODBUS REGISTER CH. A CH. B 15 Bus Active (See Note 5) - - 14 Not Used - - 13 Not Used - - 12 Not Used - - 11 Not Used - - 10 Not Used - - 9 Not Used - - 8 Not Used - - 7 Auto-Tune In Progress (See Note 4) - - 6 Auto-Tune Done (See Note 4) - - 5 Not Used - - 4 Not Used - - 3 Parameter Block Read Acknowledge (See Note 6) - - 2 Configuration Block Read Acknowledge (See Note 6) - - 1 Parameter Block Write Acknowledge (See Note 6) - - 0 Configuration Block Write Acknowledge (See Note 6) - - Status Block The Status block contains current operating values and status such as Process Value and Input Status. The DLCD continually writes the Status Block for each PID channel providing a means whereby the PLC can monitor the operating status of the DLCD. Control Block The Control block contains control values and commands, such as Set Point and Control Mode. The DLCD continually reads the Control Blocks for each PID loop from the PLC providing a means whereby the PLC program can control the DLCD. Table 2 - Control Block - Channel A and B Table 3 - Control Block for Nx:2 and Nx:6 Flags REFERENCE/ MODBUS REGISTER BIT POSITION Nx: 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 Setpoint Channel A 40002 1 Output Power Channel A 40005 2 15 14 13 7 6..5 1 0 Table 3 3 3 2 1 0 Table 4 4 Setpoint Channel B 40018 5 Output Power Channel B 40021 6 15 14 13 7 6..5 1 0 Table 3 7 3 2 1 0 Table 4 BITS REGISTER NAME MODBUS REGISTER CH. A CH. B 15 Control Mode 40041 40049 14 Disable Integral Action 40044 40052 13 Disable Setpoint Ramping 40042 40050 12 Not Used - - 11 Not Used - - 10 Not Used - - 9 Not Used - - 8 Not Used - - 7 Auto-tune Request (See Note 2) - - 6..5 Auto-tune Code 40013 40029 4 Not Used - - 3 Not Used - - 2 Not Used - - 1 Alarm Output AL2 (See Note 1) 40016 40032 0 Alarm Output AL1 (See Note 1) 40015 40031 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |